background image

5

General information

1.6 - GENERAL WARNINGS

This instruction manual is an integral and indispensable part
of the product and must be retained by the user.

Please read carefully the instructions contained in this manual
as they provide important indications regarding the safe
installation, use and servicing of this appliance.

Keep this manual in a safe place for future reference.

The installation and servicing must be carried out in
accordance with the regulations in force according to the
manufacturer’s instr uctions and by legally competent
authorized persons.

By a competent person, we imply a person who has a specific
technical qualification in the field of components for central
heating systems for domestic use, domestic hot water
production and ser vicing. The person must have the
qualifications foreseen by the current laws in force.

Bad or irregular servicing could compromise the safe
operation of the appliance, and could cause injury to persons,
animals or damage to property.

The manufacturer shall not be held liable for any such injury
and/or damage.

Before carrying out any cleaning or servicing turn off the
electrical supply to the boiler by means of the ON/OFF switch
and/or by means of the appropriate shutdown devices.

In the event of failure and/or faulty functioning of the
appliance,switch off the boiler. Do not attempt to make any
repairs: contact qualified technicians.

Any repairs must be carried out solely by  authorized
technicians and using only original spare parts. Non-
observance of the above requirement may jeopardize the
safety of the appliance.

To guarantee the efficiency and correct functioning of the
appliance it is indispensable to have the boiler serviced
annually by a qualified person.

If the boiler remains unused for long periods, ensure that any
dangerous parts are rendered innocuous.

If the appliance is sold or transferred to another owner or if the
present user moves home and leaves the appliance installed,
ensure yourself that the manual always follows the appliance
so that it can be consulted by the new owner and/or installer.

Only original accessories must be used for all appliances
supplied with optional extras or kits (including electrical ones).

This appliance must be used only for the purposes for which
it has been expressively designed. Any other use shall be
considered incorrect and therefore dangerous.

1.7 – PRESENTATION

Nowadays, the dwellings with lots of unit are adopting, more
frequently, originals forms of heating/ cooling different from
the classic system of central heating or autonomous boiler.

The modules for the central, autonomous heating 

SATAL

PLUS R 

are devices capable of providing hot water, domestic

water and heating, with room control temperature (optional)
in each single unit according to the needs.

Summary:  ALL THE  ADVATAGES  OF THE  AUTONOMOUS
HEATING WITHOT ANY INCOVENIENTS.

To make it simple, think of the hydraulic section of a combined
mural boiler hold in a special box, fed by pipes coming from
the central generator placed, for example, into the thermal
power plant or into a combined heat and power plant.

These modules  work at user command, and for monitoring
completely the activities they can be equipped of a calories
counter or an energy counter and a counter of the domestic
water consuming, for the division of the expense between all
the units and the data telecast  as well the application of the
optional domotics system.

They  answer to precise goals user:

• Self management
• Pay according to amount consumed
• Low maintenance
• Privacy

Goals of the energy supplier:
• Only flame point
• Optimization yields
• Control and Tele-management and then counting

They can be set on new or renovated buildings, but even for
the transformation from autonomous central system to
horizontal distribution

Summary of Contents for SATAL ONE PLUS R

Page 1: ...SATAL PLUS R PLUS R TRIZONA caldofreddo ice 003333659 1st edition 11 2010 INSTALLATION AND SERVICING MANUAL...

Page 2: ...16 3 6 2Local unit connections SATAL PLUS R Trizona Ice 17 3 7 Sanitary connections 18 3 8 Optional Kits 19 3 9 Electrical connections 24 General warnings 24 Connection to mains supply 230V 24 Connec...

Page 3: ...exchanger at the end of the first year and subsequently on the basis of the lime scale found this period can be extended to two years The user has to be instructed on the use and operation of his heat...

Page 4: ...the safe operation of the appliance and could cause injury to persons animals or damage to property for which the manufacturer shall not be held liable Alterations to parts connected to the appliance...

Page 5: ...at any dangerous parts are rendered innocuous If the appliance is sold or transferred to another owner or if the present user moves home and leaves the appliance installed ensure yourself that the man...

Page 6: ...circuit and the thermal head applied The model SATAL PLUS R TRIZONA ICE by two special brass header can be instantly connected to two cut with high temperature DESCRIPTION OF COMPONENTS AND FEATURES M...

Page 7: ...ng circuit low temperature zone 4 Interception cock return heating circuit high temperature zone 5 Interception cock return heating circuit low temperature zone 6 Return central circuit 7 Delivery cen...

Page 8: ...1 1 Frame 2 Interception cock delivery heating circuit high temperature zone 3 Interception cock delivery heating circuit low temperature zone 4 Interception cock return heating circuit high temperat...

Page 9: ...8 8 9 11 10 12 17 1 Interception cock inlet 2 Delivery filter 3 Mixer Valve 4 Circulator 5 Interception cock outlet 6 Calories counter Kit optional 7 Return filter 8 Non return valve 9 Hot water group...

Page 10: ...the installer flow sensor bulb holder 1 Cod 00361441 Calories counter Kit optional 2 Cod 00361763 Litres counter hot water Kit optional 3 Cod 00361764 Litres counter cold water Kit optional 2 3 1 2 5...

Page 11: ...X4D Net weight kg 15 WARNING The differential max pressure value applied to each single module must be less of 3 5 mH2O The housing module SATAL PLUS R manage the heat made by the thermal power plant...

Page 12: ...ed out by a competent engineer the whole system should be thoroughly flushed in order to remove any residual dirt or grime which could compromise correct module operation WARNING In rooms where aggres...

Page 13: ...ter protection etc out of the reach of children as they can be dangerous UNICAL refuses all liability for injury to persons animals or damage to property deriving from not having respected the above m...

Page 14: ...e wall thickness Assembly of the built in Get a niche with the same dimensions of the built in unit Set the built in unit perfectly levelled into the niche and fix it by the using of cement or silicon...

Page 15: ...e connecting the module the following requirements must be carried out by competent and qualified engineers The system is flushed out with a suitable product in order to eliminate any metallic tooling...

Page 16: ...d return circuits have to be connected to the module SATAL PLUS R via the respective connections Delivery and Return as indicated High Temperature Circuit HT Flow HT Return Low Temperature Circuit LT...

Page 17: ...be held liable for any such injury and or damage C H flow and return must be connected to the module SATAL PLUS R to the relevant 3 4 connections as shown High temperature circuit Flow 1 Return 1 Flo...

Page 18: ...esidues oil and grime which could reach the boiler and affect the proper running of the boiler Non observance of these instructions could cause injury to persons animals or damage to property The manu...

Page 19: ...o the left The thermometric probes of delivery and return are supplied in the calories counter kit The delivery probe must be connected in to the trap showed after removing the plug The return probe m...

Page 20: ...on to the connecting verse of the litres counter the direction of hot domestic water in to the circuit ACS is from the left to the right 180 470 ACS The interceptor cocks are not included in to the Ki...

Page 21: ...ntion to the connecting verse of the litres counter the direction of hot domestic water in to the circuit AFS is from the left to the right 90 560 The interceptor cocks are not included in to the Kit...

Page 22: ...ting By pass valve DWH Equipment C F M R M R DWH Equipment C F M R M R High temperature CH Low temperature CH F C F C 003 3342 6 HT LT HT HT LT 003 33 42 6 HT LT HT HT LT High temperature CH Low tempe...

Page 23: ...2 Over heating By pass valve DWH Equipment DWH Equipment Low temperature CH High temp CH 1 Low temperature CH High temp CH 2 High temp CH 1 High temp CH 2 Filter Primary system pump Secondary system...

Page 24: ...rifying in particular that the section of the system s cables is suitable to the appliance s maximum absorbed power For the appliance s general electrical supply the use of adaptors multiple sockets a...

Page 25: ...ROGRAMMI INTERROMPE ORARIO RISCALDAMENTO PROLUNGA ORARIO RISCALDAMENTO CORREZIONE MANUALE DI TEMPERATURA SE TROPPO FREDDO REGOLA FACILE ANTIGELO RISCALDAMENTO 1 RISCALDAMENTO 2 SOLO SANITARIO RISCALDA...

Page 26: ...EX remote control is not a chrono thermostat so for having the heating is necessary to combined it with thermostat ON OFF SIM PLEX remote control combined with a thermostat ON OFF 1 2 3 4 5 Y3 Y1 1 2...

Page 27: ...on to display the under parameter 03 ES ofTSP Press the button symbol is displayed select the desired value using press the button to confirm 03 ES external temperature probe value to be set 0 x Slave...

Page 28: ...connecting the terminals E Bus Y3 1 2 3 between the modules This allows to have a single external sensor for all local units It is necessary to observe the polarity Setting parameter 03 ES View previ...

Page 29: ...E OT DL1 DL2 DL3 WHITE WHITE BLACK 4 3 2 1 A1 BLUE ORANGE BLACK BROWN C D A B MMX ORANGE BROWN BLUE BLACK 3 10 WIRING SCHEME WIRING diagram of practical connection SATAL PLUS R caldofreddo LEGENDA DL1...

Page 30: ...held liable for any injury and or damage Before lighting the boiler check that the appliance installation has been carried out in accordance with the specific Standards UNI 7129 and 7131 for the gas p...

Page 31: ...ill be determined by the service engineer and will depend on the appliance s state of condition For a better operation of your appliance follow the suggested servicing as shown on the table INSTRUCTIO...

Page 32: ...g info unical ag com The Unical declines every responsibility for the possible inaccuracies if owed to errors of transcript or press Also reserves the right to bring those changes that it will hold ne...

Reviews: