Installation info
2.2.3 - ASSEMBLING THE BOILER
Before connecting the boiler to the D.H.W. and
heating system pipes, carefully clean the pi-
pes to remove all traces of metal resulting from
processing and welding operations as well as
any oil and grease which could damage the
boiler or jeopardize its operation.
To install the boiler:
-
Fix with tape the paper template to the wall
-
make two Ø 12 holes in the wall and insert
the hooks;
-
position the junction points for the connec-
tion of the gas supply pipe, cold water sup-
ply pipe, D.H.W. outlet, CH flow and return
in the positions shown by the template. ;
-
fit the boiler onto the support hooks;
Do not use solvents which
could damage the componen-
ts.
Unical
refuses all liability for
injury to persons and animals or
damage to property resulting
from non-observance of the abo-
ve.
-
connect the boiler to the gas pipe, dome-
stic cold and hot water pipes, CH flow and
return pipes.
-
connect to electrical supply
2.2.4 - VENTILATION
The boiler must be installed in a suitable room
according to the rules in force and particular-
ly:
NATURAL DRAUGHT OPEN FLUE BOILERS
(TYPE B11bs INSTALLATION and VMC)
The boliers
IVEN 04 CTN 24 F, IVEN 04 RTN
24,
are open flue boilers and are foreseen for
chimney connection: the air for combustion is
taken directly from the room in which it is in-
stalled.
The room can have both a direct ventilation
(i.e. with ventilation openings facing outwar-
ds) or an indirect ventilation (i.e. with ventila-
tion openings facing an adjacent room) provi-
ded that the following requirements are com-
plied with:
Direct ventilation:
-
The room has to have a ventilation ope-
ning of, at least,
6 cm² /kW of installed input (see input ta-
ble on par. 2.7) and, in no case, lower than
100 cm² and made directly onto an exter-
nal wall.
-
The opening has to be as close as possi-
ble to the floor.
-
It should not be possible to close it and it
should be protected with a grate not redu-
cing its usefull ventilation section.
-
A correct ventilation can be optained also
through the addition of more openings, pro-
vided the addition of the different sections
is not less than that really needed.
must have a vertical section with a length
more than twice the diameter, before get-
ting into the chimney.
2.2.5 - FLUE GAS DISCHARGE
SYSTEM
NATURAL DRAUGHT OPEN FLUE BOILERS
Connection to the chimney
A good chimney is very important for the cor-
rect functioning of the boiler; it must therefore
conform with the following requirements:
-
it must be made from waterproof material
and be resistant at the temperature of the
flue gas and relative condensate;
-
it must have sufficient mechanical stren-
gth and low thermal conductivity;
-
it must be perfectly sealed to prevent co-
oling due to parasite air inlets;
-
it must be as vertical as possible and the
end section must have a chimney cap
which guarantees efficient and constant
evacuation of the combustion products;
-
the chimney must have a diameter not
smaller than that of the boiler’s draught di-
verter; for chimneys with a square or
rectangular section, the internal section
must be 10% larger than the section of the
connection duct to the draught diverter.
-
starting from the draught diverter, the duct
-
In case it is not possible to make a venti-
lation opening close to the floor, it will be
necessary to increase its usefull section
of at least 50%.
-
If an open fire is present in the same room
it needs an indipendent air supply, othe-
rwise the installation of a type B appliance
is not permitted.
-
If in the room there are other devices whi-
ch need air for their operation (e.g. a wall
exhauster) the section of the ventilation
opening has to be the properly sized.
Indirect ventilation
In case it is not possible to make a room ven-
tilation opening on an external wall, it is pos-
sible to have an indirect ventilation, sucting
the air from an adjacent room, making an ope-
ning in the lowest part of a door.
This solution is possible only if:
-
The adjacent room is not a bed room
-
The adjacent room is not a common part
of the building and is not a room with fire
danger (e.g. a fuel deposit, a garage, etc..)
FORCED DRAUGHT ROOM SEALED BOI-
LER
(TYPE C12 - C32 - C42 - C52 - C62 - C82)
The
IVEN 04 CTFS 24 F
- IVEN 04 RTFS 24 -
IVEN 04 CTFS 28 F - IVEN 04 RTFS 28
are
forced draught, room sealed boilers; so they
do not need particular ventilation openings for
the combustion air, in the room in which they
are installed.
FORCED DRAUGHT, OPEN FLUE BOILER
(TYPE B22)
If the
IVEN 04 CTFS 24 F
- IVEN 04 RTFS 24
- IVEN 04 CTFS 28 F - IVEN 04 RTFS 28
are
installed in a room according to the chimney
configuration on type
B22,
the same ventila-
tion requirements established in paragraphs
Direct ventilation
and
Indirect ventilation
apply.