![Unical DUA plus BTN 28 Installation And User Instruction Manual Download Page 3](http://html.mh-extra.com/html/unical/dua-plus-btn-28/dua-plus-btn-28_installation-and-user-instruction-manual_839329003.webp)
3
General info
DATA PLATE DESCRIPTION
LEGEND:
1
= CE Surveillance notify body
2
=
Boiler type
3
=
Boiler model
4
=
Number of stars (Directive 92/42/CEE)
5
=
(S.N°) Serial number
6
=
P.I.N. code
7
=
Approved fluing configurations
8
=
(N0x) N0x class
A Central Heating circuit features
9
=
(Pn) Nominal output
10 = (
Pcond) Condensing nominal output
11 =
(Qmax) Nominal heat input
12 = (Adjusted Qn) Adjusted for nominal Heat input
13 =
(PMS) Max. pressure C.H. system
14 =
(T max) Max. C.H. temperature
B Domestic Hot Water circuit features
15 = (Qnw) Nominal heat input in D.H.W. mode (if different from Qn)
16 = (D) Specific D.H.W. flow rate according to EN 625-EN 13203-1
17 = (R factor) N° taps based on the quantity of water declared EN
13203-1
18 = (F factor) N°stars based on the quality of water declared
EN 13203-1
19 = (PMW) Max. pressure D.H.W. system
20 = (T max) Max. temperature D.H.W system
C Electrical features
21 = Electrical power supply
22 = Consumption
23 = Protection grade
D Countries of destination
24 = Direct and indirect country of destination
25 = Gas family
26 = Supply pressure
E Factory setting
27 =
Adjusted for gas type X
28 = Space for national brands
CE Marking
-
The CE marking documents that the boilers satisfy:
-
The essential requirements of the Directive regarding gas
appliances (Directive 90/396/CEE)
-
The essential requirements of the Directive regarding
electromagnetic compatibility (Directive 89/336/CEE)
-
The essential requirements of the Efficiency Directive (Directive
92/42/CEE)
-
The essential requirements of the low voltage Directive (Directive
73/23/CEE)
®
1
2
3
5
7
8
6
4
9
11
13
10
12
14
15
17
19
16
18
20
28
A
B
21
22
23
24
25
26
27
C
D
E