Unical ALKON 35S C User Operating Instructions Manual Download Page 4

4

User’s operating instructions

6 - OPERATING INSTRUCTIONS

6.1 - CONTROL PANEL

A = Domestic hot water temperature control

B = Summer/winter se Central heating temperature

  control knob

C = Power On indicator led(Green)

D = Central heating mode indicator led

E = Burner On indicator led(Green)

F = “RIRA” (pre-heating) mode indicator led

G = Reset /chimneysweeper mode key

H = Lock-out led indicator

I =  System temperature control/pressure gauge

Summer/winter se Central heating

temperature control knob

By turning this knob it is possible to choose

the following operating modes:

- Summer (only DHW production)

- Winter (DHW production and central hea-

ting temperature control)

When the switch is in the 

 (Summer)

position the central heating mode is exclu-

ded. However, the frost protection mode

remains enabled.

With the knob in the position indicated

in the figure, the boiler is in the “Winter”

mode, and controls the central heating

hot water flow temperature. The tempe-

rature can be adjusted between 30°C mi-

nimum and 80°C maximum.

B

C

A

D E

F

H

G

I

Domestic hot water temperature control

NOTE!

For the Alkon R model this mode is enabled

only if the boiler is connected to an external
storage tank.

With this knob it is possible to adjust the do-

mestic hot water draw-off temperature:

By turning the knob within the range indi-

cated in the figure, it is possible to adjust

the domestic hot water temperature. The

temperature can be adjusted between

35°C minimum and 57°C maximum.

Summary of Contents for ALKON 35S C

Page 1: ...00333170 2nd edition 09 2012 USER SOPERATING INSTRUCTIONS English ALKON 35S R 35S C Adjusted for 28 kW 35S R 35S C 35S R Adjusted for 25 kW...

Page 2: ...to carefully follow the instructions indicated in this guide 3 WATER TREATMENT The hardness of the mains water supply conditions the frequency with which the heat exchanger is cleaned In hard water a...

Page 3: ...held liable for any such injury and or damage 4 INFORMATION TO BE HANDED OVER TO THE USER BY THE INSTALLER 5 SAFETY WARNINGS WARNING The installation adjustment and servicing of this appliance must b...

Page 4: ...hea ting temperature control When the switch is in the Summer position the central heating mode is exclu ded However the frost protection mode remains enabled With the knob in the position indicated...

Page 5: ...en it will be necessary to restore the cor rect pressure by operating the filling valve when the system is cold and the boiler not operating Power On indicator led This led will illuminate when the bo...

Page 6: ...tomatically when the system temperature falls be low6 C the burner is automatically fired and the pump is ener gized until the system s water temperature has risen to 16 C If the temperature detected...

Page 7: ...If the boiler goes into lock out and or the leds continue to flash repeatedly or remain illuminated do not try to reset the boiler your self Contact your nearest Unical authorized Afters Sales Servic...

Page 8: ...transcript or press Also reserves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics AG S P A 46033 casteldar...

Reviews: