E N G
5 . ) # ! 4 % 2 -
3 9
7.0
END
-
OF
-
LINE COLD TESTING FUNCTION
Press Menu for two seconds and then scroll the captions using +/
-
until you reach “TEST I/0” on the screen.
This function can be accessed only when the stove is in stand
-
by mode and allows to check the
components. Only staff authorized by the Technical Assistance Service may access it and indeed it is
protected by a password.
CAPTIONS ON THE SCREEN
DESCRIPTION
Measurement Unit
CO READY
FOR
TESTING
//
C1 RESISTOR START
TESTING THE IGNITION RESISTOR
//
C2 RPM FAN SMOKE
TESTING THE SMOKE EXTRACTION
ENGINE
RPS
C3 PELLET LOAD
TESTING THE AUGER ENGINE
A
C4 AIR FAN
TESTING THE VENTILATION ENGINE
V 100%
C5 THERMOCOUPLE
TESTING THE THERMOCOUPLE
°C
C6 AIR FLOW
TESTING THE FLOW SENSOR
Volt
C7 °C TEMPERATURE SENSOR
TESTING THE ROOM AIR PROBE
°C
C8 IR PROBE TESTING
TESTING THE REMOTE CONTROLLER
PROBE
°C
C9 AUX OUTPUT
TESTING THE SERIAL CABLE OF AUX
OUTPUT
ON
-
OFF
8.0
TECHNICAL PARAMETERS
Press Menu for two seconds and then scroll the captions using +/
-
until you reach “SETTINGS” (
SETTAGGI
)
on the screen. This Menu allows to regulate the main parameters used to adjust the functions of the stove.
Only staff authorized by the technical assistance service may access it and indeed it is protected by a
password.