Unibrain Fire-i 580/780/785/980 Operation Manual
Page 45
To utilize Auto-sync, please set Bit 31 to Auto-sync Enable, and then check the Bit 27 to verify whether it is ready.
Please refer to the details in the following table.
0xF2F10018
Auto-Sync Mode control register
Bit 31 : auto sync enable
Bit 30 : SIO enable mode (0 : custom mode, 1 : IIDC v1.32)
Bit 27 : auto sync complete (read only. 1: ready, 0: not yet auto-sync)
Read/Write
4.6.
Memory Channel Save / Load
The settings of the camera features (Shutter, gain, etc.) and video modes can be stored in a non-volatile memory. The
camera supports 16 memory channels as per the table below to conveniently save and load different features as well
as video modes. Channel 0 is the factory default (preset) and Channels 1 ~ 4 can be used for saving camera
configuration. Channels 5 ~ 15 are used for resolution, mode and frame rate plus saving other features.
Address
Name
Bit
Description
618h
Memory_Save
[0]
Saves the current setting
[1..31]
Reserved
Address
Name
Bit
Description
620h
Mem_Save_Ch
[0]
Factory Default Setting Cannot overwrite
[1..4]
Write Channel for Memory Save for Channel 1 ~ 4
( Only for Features )
[5..15]
Write Channel for Memory Save for Channel 5 ~ 15
(For Features, Format and Mode Save)
Address
Name
Bit
Description
624h
Cur_Save_Ch
[0]
Read and Load Factory Default Setting
[1..4]
Read and Load Memory Channel 1 ~ 4
[5..15]
Read and Load Load Memory Channel 5 ~ 15
User Defined FireWire Register Control
The values saved in the channel are users define; and can be made the default values at power-on. The channels
from 1 to 15 are to be set in the power-on default mode.
Address
Description( bit : msb*)
Read/Write
0xF2F1011C
Power on default memory channel
Bit 0 ~ Bit 3 : power on initial memory channel
Read/Write
Example: Channel 5 is to be set the default mode at power-on.
add F2F1011C read -
5
0000000 write