UNI-T UTi260K User Manual Download Page 1

UTi260K

P/N:110401109316X

 

Professional Thermal Imager 

Summary of Contents for UTi260K

Page 1: ...UTi260K P N 110401109316X Professional Thermal Imager ...

Page 2: ...ree from any defect in material and workmanship within one year from the purchase date This warranty does not apply to damage caused by accident negligence misuse modification contamination or improper handling The dealer shall not be entitled to give any other warranty on behalf of Uni Trend If you need warranty service within the warranty period please contact your seller directly Uni Trend will...

Page 3: ...t tests the surface temperature of the object If temperature compensation is needed please adjust in the Settings menu The product has a self calibration function If the reading jumps quickly please read the temperature after it gets steady After measuring extremely high or low temperature objects please leave the product for 10 minutes before next use Do not use the product in places with strong ...

Page 4: ...ight button Back button SET button Tripod mounting hole Item Item 3 Display Display size 2 8 Display resolution 320 vertical x 240 horizontal pixels Description Description Item Item UTi260K User Manual UTi260K User Manual Center point temperature Maximum temperature Maximum temperature point Minimum temperature point Main menu Region of interest ROI 11 12 Maximum temperature point in ROI Temperat...

Page 5: ...e power button for 3 seconds to turn on off the product Note After the product starts the shutdown procedure it takes 5 to 6 seconds Please try to avoid turning on and off the product continuously to avoid damage 1 Press the SET button to open the main menu 2 Press the left right button to select the option 3 Press the SET button to enter the Measurement menu 4 Press the up down button to select C...

Page 6: ...al UTi260K User Manual 1 Press the SET button to open the main menu 2 Press the left right button to select the option 3 Press the SET button to enter the Image Mode menu 4 Press the up down button to select the desired mode from Thermal infrared image Digital visual light image Fusion image blending and PIP picture in picture 5 Press the SET button to apply the current mode 6 Press the back butto...

Page 7: ...te and Time option in the settings menu 2 Press the SET button to enter the Date and Time submenu 3 Press the left right button to select the parameter to be adjusted 4 Press the SET button to enter the parameter adjustment state 5 Press the up down button to increase or decrease the value 6 Press the SET button to save the settings and return to set other parameters 7 Press the back button to exi...

Page 8: ... increase or decrease the value 6 Press the SET button to save the current setting 7 Press the back button to exit 5 5 6 Display Brightness To set display brightness 1 Press the up down button to select the Display Brightness option in the Settings menu 2 Press the SET button to enter the Display Brightness submenu 3 Press the up down button to select the desired brightness level from Low Medium a...

Page 9: ... 4 Press the SET button to confirm 5 Press the back button to exit Note Do not remove or insert the SD card in saving pictures It is recommended to save no more than 1000 pictures so as not to affect the response speed of the product When the number of pictures exceeds 1 000 please clean up the SD card in time 5 5 10 System Settings To enter System Settings submenu 1 Press the up down button to se...

Page 10: ...System Settings submenu 2 Press the SET button to enter 3 Press the up down button to select Yes 4 Press the SET button to confirm 5 Press the back button to exit Note When formatting the SD card please do not remove it or perform other operation to avoid program errors 6 Operating Instructions 6 1 Image Capture 1 Pull and release the trigger to capture an image 2 In the manual save mode press the...

Page 11: ...eyes of people or animals 6 5 USB Communication and Image Projection 1 Download and install the PC software refer to UNI T Documents Download Operation Guide 2 Connect the USB cable to the PC 3 Set the USB mode to USB Disk to browse pictures and analyze data through the PC software set the USB mode to USB Camera to realize real time image projection through the PC software 4 Regarding the usage of...

Page 12: ...minutes off default 30 minutes 6 hours 5 hours 5V 2A Micro SD card 20 C 60 C 4 F 140 F 85 RH non condensing 15 C 30 C 59 F 86 F 85 RH non condensing 2000m User manual USB cable 16GB micro SD card Sensor Temperature range Measurement resolution Accuracy Optimal measuring distance Response time IR resolution Pixel size Color palette Infrared spectral band Field of view FOV Spatial resolution IFOV Th...

Page 13: ... Black paper Polycarbonate Concrete Copper oxide Cast iron Rust Gypsum Paint Rubber Soil Emissivity Emissivity Emissivity Note This manual can be downloaded from the official website of Uni Trend refer to UNI T Documents Download Operation Guide UTi260K User Manual UTi260K User Manual Use a wet cloth or weak soap solution to clean the outer shell of the device Do not use abrasives isopropyl alcoho...