Model UT71A/B/C/D/E: OPERATING MANUAL

l

l

l

l

l

l

l

l

l

l

l

l
l

l

When the Meter working at an effective voltage over
60V in DC or 30V rms in AC, special care should be
taken for there is danger of electric shock.
Use the proper terminals, function, and range for
your measurements.
If the value to be measured is unknown, use the
maximum measurement position.
Do not use or store the Meter in an environment of
high temperature, humidity, explosive, inflammable
and strong magnetic field.  The performance of the
M e t e r   m a y   d e t e r i o r a t e   a f t e r   d a m p e n e d .
When using the test leads, keep your fingers behind
the finger guards.
Disconnect circuit power and discharge all high-
voltage capacitors before testing resistance,
continuity, diodes.
Before measuring current, check the Meter's fuses
and turn off power to the circuit before connecting
the Meter to the circuit.
Replace the battery as soon as the battery indicator
       appears.  With a low battery, the Meter might
produce false readings that can lead to electric
shock and personal injury.

When servicing the Meter, use only the same model
number or identical electrical specifications
replacement parts.
The internal circuit of the Meter shall not be altered
at will to avoid damage of the Meter and any accident.
Soft cloth and mild detergent should be used to
clean the surface of the Meter when servicing. No
abrasive and solvent should be used to prevent the
surface of the Meter from corrosion, damage and
accident.
The Meter is suitable for indoor use.
Turn the Meter off when it is not in use and take out
the battery when not using for a long time.
Constantly check the battery as it may leak when it
has been using for some time, replace the battery
as soon as leaking appears.  A leaking battery will
damage the Meter.

Summary of Contents for UT71B

Page 1: ...amage please contact your dealer immediately 1 2 3 4 5 6 7 8 9 10 English Operating Manual Test Lead K Type nickel chromium nickel silicon Point Contact Temperature Probe It is only suitable for measu...

Page 2: ...Meter and in this Operating Manual are explained on page 9 Rules For Safe Operation Warning To avoid possible electric shock or personal injury and to avoid possible damage to the Meter or to the equi...

Page 3: ...turn off power to the circuit before connecting the Meter to the circuit Replace the battery as soon as the battery indicator appears With a low battery the Meter might produce false readings that ca...

Page 4: ...used on the Meter and in this manual are explained in Table1 2 Table 1 2 International Electrical Symbols AC or DC DC Measurement AC Measurement Grounding Double Insulated Warning Refer to the Operati...

Page 5: ...The Meter then returns to the display for the function selected with the rotary switch all previously activated button features are discarded Automatic Backlight Off Press LIGHT button to turn the bac...

Page 6: ...batteries are low and should be replaced Warning To avoid false readings which could lead to possible electric shock or personal injury replace the battery as soon as the battery icon appears The Mete...

Page 7: ...may also be influenced by some of the choices made in Setup Use the blue button to select any rotary switch alternate function labeled in blue letters When you turn the rotary switch from one function...

Page 8: ...e measurement DC millivoltage measurement Resistance measurement Power measurement Capacitance measurement Centigrade temperature measurement None None None Toggle between AC or DC voltage measurement...

Page 9: ...asurement 400 A 4000 A AC or DC current measurement 40mA 400mA AC or DC current measurement 10A Fahrenheit temperature measurement Frequency measurement Frequency signal duty cycle measurement Toggle...

Page 10: ...button e g RECALL press and hold the button for over 1 second to access this additional feature This additional feature appears right above or on the left hand side of the appropriate keys To access...

Page 11: ...UAL ranging In MANUAL select next input range EXIT to return to AUTO AUTO is default Testing resistance signal from calibrator When testing resistance signal from calibrator it is necessary to press t...

Page 12: ...lue Press EXIT to exit the Recall feature Setup feature In Setup press to select OFF at the selection of HIGH and LOW Hold feature Press HOLD to freeze the displayed value Press EXIT to release the di...

Reviews: