Accuracy Specifications (4)
F.
DC Current
Remark:
l
4A & 10A Range:
For continuous measurement 10 seconds and
interval time between 2 measurements greater than
15 minutes.
G. AC Current
Range
Accuracy
400 A
0.1 A
4000 A
1 A
(1%+2)
40mA
0.01mA
400mA
0.1mA
(1.2%+3)
4A
0.001A
10A
0.01A
(1.5%+5)
Resolution
Range Resolutio
Accuracy
400 A
A
4000 A
1 A
40mA
400mA
0.1mA
4A 0.001A
10A
0.01A
0.1
0.01mA
(1.5%+5)
(2%+5)
(2.5%+5)
Protection
Overload
10A, 250V,
fast type Glass
fuse,
5x20mm
Remarks:
l
Frequency response 40Hz ~ 400Hz.
l
Displays effective value of sine wave (mean value
l
4A & 10A Range:
For continuous measurement 10 seconds and
interval time between 2 measurements greater than
15 minutes.
response).
Overload
Protection
0.5A, 250V,
fast type Glass
fuse,
5x20mm
0.5A, 250V,
fast type Glass
fuse,
5x20mm
10A, 250V,
fast type Glass
fuse,
5x20mm