background image

3. 4- Wire RS-485 to 2-Wire RS-485 data relay 

 

 

 

 

VII. Power and surge grounding protection   

  1. External power supply: 

UT-501 

Photoelectric  Isolation  Data  Repeater  can 

adopt  the  product

s  DC9V  power  adapter  for  power 

supply or adopt power from other DC power or device. 
The  power  supply  voltage  is  +9---+12V,  current 
100mA.The connection pins are Terminal :V+,V- 

2. Surge grounding protection:   

     

Common repeater has no large energy protector. 

The transient high voltage induced in interface data 

line  tries  to  release  energy  to  the  ground  wire  via 

the  minimum  resistance  route  of  the  device  and 

thus  can  easily  cause  damage  to  interface  parts. 

ATC-109N  Photoelectric  Isolation  Data  Repeater 

can  provide  1000W  lightning  strike  and  surge 

protection  power  on  each  line. The  rapid Transient 

Voltage  Suppressor  (TVS)  can  effectively  inhibit 

lightning  and  ESD.  ATC-109N  Photoelectric 

Isolation  Data  Repeater  terminal  Pin  FGND  is 

designed  for  surge  grounding  protection.  The  user 

shall try to avoid hanging by credible grounding to 

ensure  the  safety  of  communication  during 

operation 

VIII. Trouble shooting 

1.  Data transmission failure:   

A.  check  to  make  sure  the  RS-422  interface  is 

correctly connected 

B.  check  to  make  sure  the  RS-485  interface  is 

correctly connected 

C.  check  to  make  sure  the  power  supply  voltage 

and polarity are correct. 

2. Data loss or    error: 

A.  Check  the  consistency  of  the  data  speeds  and 

formats at the both ends of the data communication 

device. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 