![UNI-T UT219PV User Manual Download Page 25](http://html2.mh-extra.com/html/uni-t/ut219pv/ut219pv_user-manual_4837484025.webp)
UT219PV User Manual
25
/
27
9.999kΩ
0.001kΩ
99.99kΩ
0.01kΩ
* Precision range: 1~100% of range
*For continuity test at 999.9Ω, fast response cannot be achieved. For resistance ≤30Ω, continuous
sound is generated and green backlight is lit up. For resistance ≥50Ω, no sound is made.
8. Diode
Range
Resolution
Overload protection
2.800V
0.001V
1500V AC/DC
* Open-circuit voltage: About 3 V
* Residual reading under short-circuit condition: ≤3 digits
9. Capacitance
Range
Resolution
Accuracy
Overload protection
100.0μF
0.1μF
±(1.0%+5)
1500V AC/DC
1000μF
1μF
* Residual reading under open-circuit condition: ≤5 digits
* Measured value = Displayed value - Residual reading
* Precision range: 5~100% of range
10. Temperature
Range
Resolution
Accuracy
Overload protection
-40
℃
~400
℃
0.1
℃
±(1.0%+30)
1500V AC/DC
-40
℉
~752
℉
0.2
℉
±(1.0%+60)
* Equipped with Type K (NiCr~NiSi) thermocouple
* Open-circuit indication: OL
* Short-circuit indication: Ambient temperature
* If each ambient temperature difference of the Clamp Meter reaches ±5
℃
, the accuracy can be
adopted after 1 hour.
11. Table of Auto Hold Function
Table of Auto HOLD Function
Function
Threshold
Fluctuation range/Increment
ACV
10V
2V
DCV
10V
2V
Ω
99.99KΩ
2.0Ω/20Ω/0.2KΩ