![UNI-T UT136A Operating Manual Download Page 2](http://html.mh-extra.com/html/uni-t/ut136a/ut136a_operating-manual_838886002.webp)
Range
Resolution
Accuracy
ȍ
ȍ
±(1.2% + 2)
.ȍ
.ȍ
Nȍ
Nȍ
±(1% + 2)
Nȍ
Nȍ
0ȍ
0ȍ
±(1.2% + 2)
0ȍ
0ȍ
±(1.5% + 2)
Overload Protection: 500V AC/ DC
7. Diode, Continuity Test
Function Resolution Remark
0.001V Display positive voltage decline
ȍEX]]H
r
!ȍPD\RU
PD\QRWEX]]HU
Overload Protection: 500V DC / AC.
8. Frequency and duty cycle
Range
Resolution
Accuracy
+]
+]
±
+]
+]
.+]
.+]
.+]
.+]
(0.5%+3)
.+]
.+]
0+]
0+]
0+]
0+]
0.1~99.9% 0.1% For refer only
9. Temperature Measurement(For UT136C only)
Range
Resolution
Accuracy
-40~0
ć
-(8% +5)
0~400
ć
1
ć
±(2.5%+3)
400~1000
ć
±(3% +3)
Overload Protection: 500V DC /AC.
Enclosed point contact K type thermocouple can
only
E
e used on less than 230
ć
temperature
measurement.
10. NCV (For UT136D only)
Function
Range
Remarks
PPEX]]HUEHHSV
1&99+]
aPPPD\DQGPD\QRWEHHSV
!PP%X]]HUQRWVRXQG
Maintenance And Service
Warning
Make sure the test leads take off the terminal and the
circuit as well as power off the meter if want to open
the meter cover.
1.General Service and Maintenance
Periodically wipe the case with a damp cloth and mild
GHWHUJHQW'RQRWXVHDEUDVLYHVRUVROYHQWV
Any
DEQ
ormal on the meter, stop use the meter and
return to service center.
When need to have cali
E
ration on the meter, please
allow certi
¿
ed engineer or speci
¿
c service center for
the service maintenance.
2. LCD display “
” sign indicating
EDWWHU\
will
EH
run out and need to replace a new
EDWWHU
y, if fail to do
that. It causes the variance of the measuring result.
Battery Specification: 9V 6F22 or NEDA 1604/
IEC6LR61
Operating Steps:
(1) Turn the power in “ off "situation, then remove the
test lead out of the meter.
(2) Use screwdriver to take off the screw on the
E
attery cover. Then you can take off old
E
attery for
replacing.
(3) User screwdriver to take off two pieces of screws,
then you can replacing the
E
urned fuse(s) as
replacement.
)XVHVSHFL¿FDWLRQ
))XVHijîPP)
A H 250V
))XVHijîPP)
A H 250V
¿JXUH
3ODFHWKHWHVWOHDGVWRWKHFLUFXLWZKLFKEHWHVWHG
if
E
etween
E
oth terminals show resistance >100
ȍ
. it
is a short-circuit, no
EX]]H
r. if
EHWZHHQ ERWK
terminals
show resistance
10
ȍ
, it is a good connection with
continually
E
u
]]
er. if
E
etween
E
oth terminals show
UHVLVWDQFH!ȍPD\RUPD\QRWEX]]H
r.
2. Resistance value on tested circuit display on LCD.
8QLWLVȍ
Note:
1. To maintain the diodes measurement accuracy
disconnect circuit power and discharge all the high
YROWDJHFDSDFLWRUVEHIRUHWKHPHDVXULQJ
2. For the continuity testing, the open circuit for
voltage is 0.5V.
3. Do not input higher than DC 60V and AC 30V rms
voltage to prevent any damage and accident.
G. Frequency and Duty Cycle Measurement
(see
¿JXUH
¿JXUH
1. Connect the test leads across with the
REMHFW EHLQJ
measured. The measured value shows on the display.
2.If you need to measure duty cycle, press SELECT
EXWWRQWRVHOHFWPHDVXUHPHQWPRGH
Note:
Input Amplitude: a
:KHQ.+]D!P9UPV
:KHQ!.+]D!P9UPV
Never input higher than 10V rms for test frequency
and duty cycle.
H. Temperature Measurement
( only UT136C, see
¿JXUH
¿JXUH
1. Turn rotary switch to“
ć
”.
2. Put the multiple purpose socket into the correct
terminal. K-Type point contact temperature pro
E
e
can only
EH
used in the measurement
EHORZ
230
ćˈ
if you want to measure over 230
ć
, you need to
VHSDUDWHO\EX\DQRWKHUWHPSHUDWXUHSUREH
3. The LCD displays “OL” indicating point contact
temperature
SUREH
which take off. When short circuit
E
etween
ć
terminal and COM terminal, the meter
show the value of room temperature.
I. NCV Function
( UT136D only
VHH¿JXUH
¿JXUH
1. Set the rotary switch to NCV and remove the test
lead from the input terminals.
2. Place the housing front part with marking towards
the 220V/50H
] E
eing measured. Distance <10mm,
the m
HWHUEX]]HU
mm<Distance <50mm, the meter
may or may not
EX]]HU
Distance >50mm, the meter
QRWEX]]HUDQGWKH/&'GL
splays “OL”.
UT136A/B/C/D Operating Manual
$FFXUDF\6SHFL¿FDWLRQV
$FFXUDF\DUHDGLQJEGLJLWVJXDUDQWHHIRU\HDU
Operating temperature: 23
ć
±5
ć
Relative Humidity: <75%
1. DC Voltage
Range
Resolution
Accuracy
400mV
0.1mV ±(0.8% + 3)
4V
0.001V
40V
0.01V ±(0.8% + 1)
400V
0.1V
500V
1V
Input impedance: all range
0ȍ
Maximum input voltage: 500V AC/DC.
2. AC Voltage
Range
Resolution
Accuracy
400mV
0.1mV
±(1.2% + 5)
4V
0.001V
40V
0.01V
±(1.2% + 3)
400V
0.1V
500V
1V
Input impedance: a
E
out 10M
ȍ
Maximum input
voltage: 500V AC/DC
)U]a+]
Display effective value of sine wave( average value)
each measurement is applic
DEOH
from 5% of range as
reference.
3. Capacitance (UT136B only)
Range
Resolution
Accuracy
4nF
0.001nF For refer only
40nF
0.01nF
400nF
0.1nF
±(4% + 3)
ȝ)
ȝ)
ȝ)
ȝ)
ȝ)
ȝ)
±(5% + 10)
Overload Protection: 500V AC / DC
4. DC Current
Range
Resolution
Accuracy
ȝ$
ȝ$
ȝ$
ȝ$
40mA
0.01mA
400mA
0.1mA
4A
0.001A
10A
0.01A
Overload Protection:
mA
UDQJH)IXVHijîPP)
A H 250V
10A
UDQJH)IXVHijîPP)
A H 250V
When
5A Continuous measurement is allowed,
When
˘
5A Continuous measurement less than 10
seconds at an interval more than 15 minutes.
5. AC Current
Range
Resolution
Accuracy
ȝ$
ȝ$
ȝ$
ȝ$
40mA
0.01mA
400mA
0.1mA
4A
0.001A
10A
0.01A
Overload Protection:
mA
UDQJH)IXVHijîPP)
A H 250V
10A
UDQJH)IXVHijîPP)
A H 250V
When
5A Continuous measurement is allowed,
When > 5A Continuous measurement less than 10
seconds at an interval more than 15 minutes.
)U]a+]
Display effective value of sine wave( average value)
each measurement is applic
DEOH
from 5% of range as
reference.
6. Resistance
±(1% + 2)
±(1.2% + 3)
±(1.5% + 5)
±(1.2% + 5)
±(1.5% + 3)
±(2% + 3)
ȍ
P/N: 110401103485