7
8
Manual mode
When the instrument is OFF, long press manual/pulse
button for more than 3 seconds to turn on the instrument
and it will enter manual mode. The angle of laser beam
can be set as needed. In self-leveling/manual mode, LED
indicator lights up red. Long press manual/pulse button
again for more than 2 seconds, the instrument will turn off.
Overrange sensing is OFF in manual mode and the laser
beam flashes every 5 seconds to indicate that the manual
mode is ON.
Note: In manual mode, the projected laser cannot be used
as horizontal or vertical reference laser.
Pulse mode
When the instrument is ON, short press manual/pulse
button to enter pulse mode, the brightness of laser beam
will decrease and the pulse indicator light up blue, the
receiver can be used at this time. Short press manual/
pulse button to exit pulse mode, and then the pulse indicator
lights off.
Function description
The instrument can generate four vertical laser beams,
one horizontal 360° laser beam and one aligning point.
When the instrument is ON, the logic sequence defaults
at vertical laser, horizontal laser and aligning point.
Short press H button to turn on/off horizontal laser beam
and aligning point.
Short press V button to switch
vertical laser beams.
among
Specification
Laser type
Laser wave length
Laser power
Laser class
Laser number
Horizontal accuracy
Vertical accuracy
Laser width
Distance from ground
Emitting angle
Working distance
Working temperature
Storage temperature
Outdoor pulse
Leveling time
Leveling range
Leveling type
Battery type
Battery capacity
Dimension
Working time
LD green light
520nm±5nm
30mW
Class II
8 beams
≤±
3mm/10m (
60 )
±
''
≤±
3mm/10m (
60 )
±
''
<4mm/10m
(Indoor light: 80~100lux)
≤
20mm
Horizontal 360°, vertical 120°
30m
-10 40°C
~
-10 40°C
~
Pulse (5:5) mode
≤
3 seconds
3°
1°
±
Magnetic damping type,
heavy bob type
Lithium battery pack (including
2 pieces of 18650 batteries)
5200mAh with Type-C port
138.3mm×89.5mm×136.4mm
4 hours
LM585LD User Manual