background image

1

6

5

4

3

2

0.000 m

0.00 ft

0  1/16 in

0.0 in

0.00 m

2

0.000 m

2

0.00 ft

2

0.00 ft

2

0.00 ft

2

0.00 ft

2

0.00 m

3

0.000 m

3

0.00 ft

3

0.00 ft

3

0.00 ft

3

0.00 ft

3

0.00 m

0

'

00

"

 

 1/16

P/N:110401110183X

LM50A/LM70A/LM100A/LM120A

Laser Distance Meter 
User Manual

Safety Information

Before using the meter for the first time, please read the safety information 
and operating instructions carefully.

  

Use the meter only as specified in this manual. Otherwise, it may cause 

  

damage to the meter, affect measurement accuracy and result in personal 

  

injury.

  

Do not disassemble or repair the meter without authorization. Do not refit 

  

or change the performance of the laser transmitter illegally. Please keep 

  

the meter properly, do not place it where children can reach it, and avoid 

  

use by irrelevant personnel.

  

Do not irradiate the laser at eyes and other parts of the body , and on the 

  

surface of highly reflective objects.

  

The electromagnetic radiation of the meter may cause interference to other 

  

equipment. Please do not use the meter near airplanes, medical equipment 

  

or in flammable and explosive environments.

  

The replaced batteries and discarded meters cannot be disposed of together 

  

with domestic garbage. Please dispose of them in accordance with 

  

relevant national or local laws and regulations.

  

If the meter has any quality problems, or if users have any questions about 

  

the use of the meter, please contact the local dealer or manufacturer in time.

Battery status

Data storage

Laser indication

Max

Length measurement

Area/volume/triangle 
measurement

Min

Secondary display

Primary display

Product Introduction

Display

Keypad

On/measure

Subtract/sound

Add

Area/volume/triangle

Measurement reference/
unit selection

Off/clear

Log

1. Open the battery door on the back of the meter, install the battery according 
    to the polarity instructions, and close the battery door.
2. The meter can only use 1.5V AAA alkaline batteries.
3. When the meter is not used for a long time, please take out the battery to 
    prevent it from corroding the meter's main body.

Batteries

Power On and Function Settings

1. Power On/Off

    In the shutdown state, press       , the meter and the laser will be started 
    at the same time.
    In the power-on state, press and hold         for 3 seconds to turn off the 
    meter. If no operation is performed within 150 seconds, the meter will 
    automatically shut down.

2. Unit Settings

    Long press      to enter the unit setting state and the current unit can be 

    reset. The default unit of the meter is 0.000m. There are 6 optional units.

Measurement units:

Length

Area

Volume

3. Measurement Reference Settings

Short press      to measure from front or end. The default setting is end 
measurement.

4. Backlight

The backlight is automatically turned on and off. It will turn on for 15 seconds 
when any button is pressed. The backlight will automatically turn off if there 
is no operation after 15 seconds to save power.

5. Sound

Long press     to turn on or off the sound of the beeper.

6. Self-Calibration

Self-calibration function can ensure the measurement accuracy.
Calibration method: In the shutdown state, press and hold       , and then 
short press       to turn on the meter. When the screen shows '         ' with a 
flashing number at the bottom, the meter enters the self-calibration mode. 
At this time, users can press       to calibrate values according to the error 
of the meter.
Calibration range: -9~9mm

Examples:  The actual distance is 3.780m.
If the measured value is 3.778m, which is 2mm smaller than the actual value, 
press 

+

 to increase the calibration value by 2mm.

If the measured value is 3.783m, which is 3mm larger than the actual value, 
press      to lower the calibration value by 3mm.
After adjustment, press       to save the calibration results.

Measurement Modes

1. Single Measurement

While the meter is on, press      to transmit the laser. Press     again to make 
the distance measurement. The measurement results will show on the 
primary display.

2. Continuous Measurement

While the meter is on, long press      to enter the continuous measurement 
state. The maximum and minimum values during the measurement will show 
on the secondary display. The measurement results will show on the primary 
display. Short press     or       to exit the continuous measurement.

3. Area Measurement

Press 

FUNC

 1x. The        symbol will appear on the display and one side of 

the rectangle will flash.
Press      to make the first measurement (length).
Press      again to make the second measurement (width).
The meter will automatically calculate the area, and the result will show on 
the primary display. The length and width will show on the secondary display.
During the measurement process, press        to clear the measurement result 
and re-measure.
Press         to exit the area measurement and enter the length measurement 
mode.

4. Volume Measurement

Press 

FUNC

 2x. The      symbol will appear on the display.

Press      to make the first measurement (length).
Press      again to make the second measurement (width).
Press      again to make the third measurement (height).
The meter will automatically calculate the volume, and the result will show 
on the primary display. The length, width and height will show on the secondary 
display.
During the measurement process, press        to clear the measurement result 
and re-measure.
Press         to exit the volume measurement and enter the length measurement 
mode.

5. Indirect Measurement

The meter has four modes that use the Pythagorean theorem to measure 
the distance of one side of a triangle, which is convenient for users to perform 
indirect measurement in a complex environment.

Reviews: