Uni-ram UM80 Series User Manual Download Page 5

5

MANUAL -  WALL MOUNT WATERBORNE GUN CLEANERS - UM80 SERIES  REVISED 2015-5-30

•  Clean the Cap by rubbing it on the Flat Brush mounted on the inside of the tank.

•   Exterior Cleaning - Clean the exterior of the gun with the Flow-through brush. Activate the flow of liq-

uid through the Brush by turning the long arm of the Selector Knob to the left to the Brush position.
When finished, turn it to the closed position.

UM80S 
The S model does not have a whip line. Follow the procedure above starting with Interior Cleaning

UM80W / WF / A
•  Dry Spray Gun: Use the Air Blow Gun to dry the outside of the spray gun. To dry the paint channel, 

squeeze the trigger of the spray gun.

•  Flow Control: To adjust the flow of water through the Nozzle, use the control on the right side. The 

controls are pre-set at the factory - change only if necessary. To increase the flow, loosen the nut, 
then turn the knob to the left. To reduce the flow loosen the nut, turn the knob to the right. 

UM80S 

•   Dry Spray Gun: Use the Air Blow Gun to dry the paint channel and the outside of the spray gun.

•   Flow Control: The "S" model has a flow control for the Nozzle and Brush on the right side of the unit.   

The controls are pre-set at the factory - change only if necessary. To increase the flow, loosen the 
nut, then turn the knob to the left. To reduce the flow loosen the nut, turn the knob to the right.

CAUTION: MAKE SURE THE GUNS ARE COMPLETELY DRY AFTER USE

FLOCCULATION (WF Model Only)

The dirty water from cleaning accumulates in the flocculation reservoir during use. When the Wash Pail is 
empty follow these steps to treat the water for re-use:

• 

Remove the Screen at the bottom of the work area and sprinkle 1 full scoop of the flocculant, 
COAG-KLEEN, evenly over the dirty water. Replace the screen and turn the Flocculation Timer 
fully to the 5 minute position. When the Timer is finished wait one minute and then turn the timer a 
second time to the one minute mark. Note: As the flocculation proceeds, the water should become 
clear. The debris consisting of paint absorbed into the flocculant will collect in the filters during the 
next step.

• 

To allow the water-flocculant mixture to flow into filters, open the Flocculation Drain valve. 

• 

Clean the tank with the Brush. 

• 

Close the Flocculation Drain valve (horizontal position).

• 

Ensure that the Air Agitator in the bottom of the tank lies flat.

• 

Leave the two filters containing the debris in place until the next day to allow for them to dry 
throughly. When the debris is dry, it should have an "oatmeal like" consistency. The debris can now 
be disposed of according to local environmental regulations.

• 

If the filtered water is not clean, see the Troubleshooting section.

• 

The treated water can be reused until it becomes "silky" to the touch and then it should be dis-
posed of according to local environmental regulations. When adding fresh water, refill until the 
water reaches the bottom of the filter holder.

Summary of Contents for UM80 Series

Page 1: ...0 SERIES WALL MOUNT SPRAY GUN CLEANERS WATER BORNE UM80W UM80WA UM80WF SOLVENT BORNE UM80S UNI RAM CORPORATION ONTARIO CANADA CAUTION DO NOT USE WATER BORNE UNITS WITH SOLVENT BORNE PAINT OR SOLVENT B...

Page 2: ...N The air supply must be free from contaminants such as water dust rust tar grease etc To prevent damage to the Diaphragm Pump an internal Air Pressure Regulator has been installed to limit the air pr...

Page 3: ...ube thick into it Place the pail under the unit Replace the dirty solvent with clean solvent when needed CLEANING SELECTOR KNOB Position the long arm of the selector knob in the verticle position and...

Page 4: ...MANUAL WALL MOUNT WATERBORNE GUN CLEANERS UM80 SERIES REVISED 2015 5 30 4 UM80W UM80WA UM80W UM80WA UM80S UM80S FRONT RIGHT SIDE...

Page 5: ...UTION MAKE SURE THE GUNS ARE COMPLETELY DRY AFTER USE FLOCCULATION WF Model Only The dirty water from cleaning accumulates in the flocculation reservoir during use When the Wash Pail is empty follow t...

Page 6: ...MANUAL WALL MOUNT WATERBORNE GUN CLEANERS UM80 SERIES REVISED 2015 5 30 6 UM80WA HAS ADDTIONAL AIR OUTLET FOR EXTERNAL FLOCCULATION UM80W UM80WA UM80S LEFT SIDE...

Page 7: ...t cycling the spool valve has stalled due to a blocked air passage Follow the procedure below to clear the blockage Connect a blow gun to an 60 PSI source Locate the blue hose that extends from the ai...

Page 8: ...q uid Line Replace pump WASH LIQUID DOES NOT FLOW PUMP DOES NOT MAKE A NOISE Pump leaks Replace pump Blockage in air passage Follow Procedure 3 Blocked Passage in Air Line UM80WF ONLY FILTERED WATER I...

Page 9: ...9 MANUAL WALL MOUNT WATERBORNE GUN CLEANERS UM80 SERIES REVISED 2015 5 30 FLOW DIAGRAM UM80W WA Model not shown Use the diagram to trace the flow of compressed air and water...

Page 10: ...MANUAL WALL MOUNT WATERBORNE GUN CLEANERS UM80 SERIES REVISED 2015 5 30 10 FLOW DIAGRAM UM80WF Use the diagram to trace the flow of compressed air and water...

Page 11: ...11 MANUAL WALL MOUNT WATERBORNE GUN CLEANERS UM80 SERIES REVISED 2015 5 30 FLOW DIAGRAM UM80S Use the diagram to trace the flow of compressed air and water...

Page 12: ...ER 102 8200 COAG KLEEN FLOCCULANT 102 8300 FILTER BAG PRIMARY 102 8125 FILTER BAG SECONDARY 102 8126 FILTER HOLDER 102 8120 WASH PAIL UM80WF ONLY 103 8111P 5 LITRE BOTTLE TYPE CONTAINER 103 8111B WASH...

Page 13: ...a new pump free of charge and arrange for the return of your original pump Conditions of Warranty As Uni ram Corporation has no control over the working conditions or circumstances under which the pu...

Reviews: