6
MANUAL - UG4000 SERIES SPRAY GUN CLEANERS
REVISED 2019-02
ITEM
DESCRIPTION
ITEM
DESCRIPTION
1
GROUND WIRE
8
OVERFLOW TUBE
2
TRANSFER OUT HOSE TO RECYCLER
9
RINSE PUMP
3
DRAIN HOSE
10
AIR SUPPLY FOR RINSE PUMP
4
SUCTION TUBE FOR FLOW-THROUGH
BRUSH
11
GROUND WIRE
5
SUCTION TUPE FOR AUTO WASH
12
CLEAN PAIL
6
WASH PAIL
13
TRANSFER IN HOSE FROM RECYCLER
7
DRAIN VALVE (HORIZONTAL=CLOSED)
PAIL SETUP - UG4000E and UG4500E
GUN CLEANER - SOLVENT RECYCER COMBINATION UNITS
1
2
3
4
5
6
7
8
9
10
11
12
13
PAIL SETUP - UG4000E and UG4500E
•
Combo Ready units (UG4000E and UG4500E) come with the pails already installed as shown.
Transfer Hoses are provided with Uni-ram Solvent Recyclers designed for Combo operation.
•
Fill the Wash Pail with about 3 Gal (12 L) of clean solvent.
•
Fill the Rinse Pail with about 5 Gal (19 L) of clean solvent (about 1“ below the overflow pipe).
•
After setting up the pails, make sure the Drain Valve is open (handle is in the vertical position).