background image

14

MANUAL -  UG2000DM SERIES SPRAY GUN CLEANERS 

 

 

REVISED 2018-12

REPLACEMENT PARTS

 

P

art No.  

 

Description 

 

110-430 

            Nozzle Adapter, Push On, Conventional Systems Only   

 

 

110-430PPS 

 

Nozzle Adapter, Push On, Disposable and Conventional Systems 

 

780-3530 

 

Nozzle Adapter, Disposable Cup Systems Only   

 

 100-413F 

 Paint 

Cap 

Holder  

 115-200/K 

 Mechanical 

Timer 

Assembly, 

minutes

 140-230  Air 

Passage 

Plug

 

140-2340 

 

Trigger Clamp & Plug Kit

 113-800  Flow-Through 

Brush 

Assembly 

  

 

100-8335 

 

GROUND WIRE,14G, GREEN, 36" L 

 

 

100-835 

 

GROUND WIRE,18AWG, GREEN, 4 FT

 

UDP4TA 

 

DUAL DIAPHRAGM PUMP, 4"

 
 

 

 

 

Summary of Contents for UG2000DM Series

Page 1: ...REV 2018 12 USER MANUAL UG2000DM SERIES AUTOMATIC SPRAY GUN CLEANERS Uni ram Corporation www uniram com 381 Bentley St 905 477 5911 Markham On L3R 1P7 sales uniram com...

Page 2: ...Size and Weight 28 W x 17 D x 42 H 91 LBS 41 KG CAUTIONS AND WARNINGS Always disconnect this machine from power sources before performing maintenance Do not smoke or use near open flames sparks or hea...

Page 3: ...G2000DM SERIES SPRAY GUN CLEANERS REVISED 2018 12 Drain Valve inside Drain Hose Suction hose for Wash pail and suction hose for brush Wash Pail Foot petal for brush Timer UG2000DM FIGURE 1 Cleaning Ta...

Page 4: ...he Diaphragm Pump an internal Air Pressure Regulator has been installed to limit the air pressure to 85 PSI Do not install a second air pressure regulator or use a pressure set below 85 PSI GROUNDING...

Page 5: ...wn in B photo Pull the gun s trigger to flush the solvent through the fluid channel Dispose of solvent in the waste container not supplied Do not mix water and solvent waste Disposable Cup A B CLEANIN...

Page 6: ...ISED 2018 12 SPRAY GUN INSTALLED IN TANK INSTALLING SPRAY GUNS IN TANK Place the spray gun on the nozzle with the cap facing the corner Nozzle Extension for disposable cups Location for Push On Nozzle...

Page 7: ...7 MANUAL UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2018 12...

Page 8: ...tank Step on the foot pedal A dedicated pump delivers wash solvent through the brush left photo below To control the flow of solvent through the Brush adjust the Flow Control also on the front of the...

Page 9: ...filter in a cup of solvent Wash Pail Remove Suction Pipe and Filter Filter REPLACING SOLVENT Replace the solvent when the solvent has lost cleaning effectiveness or after approximately 100 cleanings C...

Page 10: ...if less than1 2 full Fill to 3 gal 11 L Debris in pump or suction and output hose Follow Procedure 1 Blocked Fluid Passage in Diaphragm pump WASH PUMP MAKES HISSING SOUND AND SOLVENT DOES NOT FLOW Wa...

Page 11: ...r adapter Incompatible solvent p p solvent formulated for type of paint Low pressure in air supply p of 85 PSI Plugged jets y g through the jets If not successful SOLVENT APPEARS RED or ORANGE Water i...

Page 12: ...here is a steady hissing sound and the pump is not cycling the spool valve has stalled due to a blocked air pas sage Follow the procedure below to clear the blockage Connect a blow gun to an 85 PSI so...

Page 13: ...13 MANUAL UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2018 12 UG4000E FLOW DIAGRAM Use the diagram to trace the flow of compressed air and solvent...

Page 14: ...e Adapter Push On Disposable and Conventional Systems 780 3530 Nozzle Adapter Disposable Cup Systems Only 100 413F Paint Cap Holder 115 200 K Mechanical Timer Assembly 5 minutes 140 230 Air Passage Pl...

Page 15: ...for the return of your original pump Conditions of Warranty As Uni ram Corporation has no control over the working conditions or circumstances under which the purchaser stores handles or uses the prod...