Unit Diagram

Cleaning the Filter

1. Unplug the unit.

2. For PreFilter:

Pump Maintenance

Your Unip Pro 120X is equipped with an integral condensate pump designed to pump 
water from the dehumidifier out to the desired drain. The pump requires routine maintenance 
that is not covered by the warranty.

Maintenance

**

For more detailed instructions, visit www.unipdry.com**

WARNING: Always unplug the unit before doing any maintenance.

Cleaning the Machine Body

• Use a soft, damp cloth to clean the exterior of unit. Do not use any
soap or solvents

Coil Maintenance

Once per year, clean the coils with an approved coil cleaner. The

 

coil cleaner should be a self-rinsing, 

foaming, cleaner, such as

 

WEB® Coil Cleaner.

Handle

Side Panel

Filter Cover

Control Panel

Pre-Filter

Discharge Grille

Power Cord

Auxiliary Terminals

Drain Hose 
Connection

a. Remove prefilter from inlet of machine.
b. Vacuum or wash with warm water (no soap).

3. For MERV-10/HEPA/Carbon Filters:

a. Replace as necessary- we recommend checking the filters
at least 1x/year

Electrical Access

• 

• Remove the screw on the

control board cover.

Unscrew the 13 screws on the side panel.

Preventative maintenance is necessary to prevent issues from dirt and

 

slime that may 

accumulate in the drain system. This includes the drain

 

pan, hose to the condensate pump, 

pump reservoir, pump head assembly,

 

and discharge tubing

Removing the Pump

1. Remove the 13 screws on the side panel and set panel aside.
2. Remove the screw holding the pump in place.
3. Undo the 3 pump electrical quick connects and 1

 

drain quick connect

4. Insert a flat head screwdriver into the notch
on the side of the pump. This will allow you to
gently lift the pump off its reservoir (the reservoir
remains attached to the unit)..

Summary of Contents for Pro 200X

Page 1: ...Uni P Pro 200X Dehumdifiers Installation Operation Service Instructions Add 4240 Latham Street Suite D Riverside CA 92501 Tel 888 990 7469 E mail sales unipdry com READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...ctions you will typically need to test the operation of the trip circuit monthly For ease of testing and operation it may be helpful to put the test switch and indicator lights in a convenient locatio...

Page 3: ...nlet needs a minimum of 12 clearance and the discharge requires a minimum of 36 clearance Unipdry dehumidifiers are only intended for operation when the unit is upright and level with the feet on the...

Page 4: ...lly open at the accessory float switch If an E4 error occurs immediately switch the wiring to N C normally closed on external switch You may need to unplug the unit to reset the error code 6 Auxillary...

Page 5: ...l is being utilized The symbol on the display indicates the sensor on the dehumidifier is being utilized 4 Temperature The T button changes the temperature reading on your remote The remote comes from...

Page 6: ...r such as WEB Coil Cleaner Handle Side Panel Filter Cover Control Panel Pre Filter Discharge Grille Power Cord Auxiliary Terminals Drain Hose Connection a Remove prefilter from inlet of machine b Vacu...

Page 7: ...over so you have access to the pump 3 Remove the pump head from the reservoir by unscrewing the screw Wipe reservoir clean with a paper towel 4 Reassemble pump 5 Mix a 16 ounce solution of bleach 1 oz...

Page 8: ...ture so it is within operating range below 105 If error stille displays check the sensor Identify all sources connected to outlet and confirm source of trip If it is dehumidifier contact technical sup...

Page 9: ...ontact Unipdry Tech Support by phone 888 990 7469 to receive a Return Authorization RA number 3 Once an RA has been issued it is the customer s job to bring the unit to a certified repair center If th...