Tel: 888-990-7469
Tel: 888-990-7469
8
9
Uni-P Pro 200X Dehumidifier
Installation, Operation & Service Instructions
Uni-P Pro 200X Dehumidifier
Installation, Operation & Service Instructions
Unit Diagram
Cleaning the Filter
1. Unplug the unit.
2. For PreFilter:
Pump Maintenance
Your Unip Pro 120X is equipped with an integral condensate pump designed to pump
water from the dehumidifier out to the desired drain. The pump requires routine maintenance
that is not covered by the warranty.
Maintenance
**
For more detailed instructions, visit www.unipdry.com**
WARNING: Always unplug the unit before doing any maintenance.
Cleaning the Machine Body
• Use a soft, damp cloth to clean the exterior of unit. Do not use any
soap or solvents
Coil Maintenance
Once per year, clean the coils with an approved coil cleaner. The
coil cleaner should be a self-rinsing,
foaming, cleaner, such as
WEB® Coil Cleaner.
Handle
Side Panel
Filter Cover
Control Panel
Pre-Filter
Discharge Grille
Power Cord
Auxiliary Terminals
Drain Hose
Connection
a. Remove prefilter from inlet of machine.
b. Vacuum or wash with warm water (no soap).
3. For MERV-10/HEPA/Carbon Filters:
a. Replace as necessary- we recommend checking the filters
at least 1x/year
Electrical Access
•
• Remove the screw on the
control board cover.
Unscrew the 13 screws on the side panel.
Preventative maintenance is necessary to prevent issues from dirt and
slime that may
accumulate in the drain system. This includes the drain
pan, hose to the condensate pump,
pump reservoir, pump head assembly,
and discharge tubing
Removing the Pump
1. Remove the 13 screws on the side panel and set panel aside.
2. Remove the screw holding the pump in place.
3. Undo the 3 pump electrical quick connects and 1
drain quick connect
4. Insert a flat head screwdriver into the notch
on the side of the pump. This will allow you to
gently lift the pump off its reservoir (the reservoir
remains attached to the unit)..