Last Updated: 08/11/2022
Light should be fused with 5 Amp Fuse (
ATM05 sold separately
)
Wire Colour
Function
Connect To
Red
Black
Yellow
Power
Ground
Pattern Selection & Synchronization
+12/24 V DC
- Ground
+12/24 V DC
- Once to the next pattern
- Quickly 3 times to flash pattern #1
Briefly Connect Pattern Selection wire (Yellow wire) to Power wire (Red wire)
All lamps must be set to the same pattern before synchronization.
Connect Yellow Wires of all units together for synchronization.
INST
ALLA
TION MANU
AL
E-2215 Series
Wiring Information
(switches sold separately)
Flash Pattern button
ON/OFF button
Pattern Selection
ON/OFF Switch
Flash Pattern Button
- Once to the next pattern
- Quickly 3 times to flash pattern #1
Momentarily press the button
Synchronization
Flash Patterns
NO.
Flash Patterns
1
2
3
4
5
6
7
8
9
10
11
12
Random Patterns
Rotating Flash
Alternating Single Flash
Alternating Double Flash
Alternating Quad Flash
Alternating Quint Flash
Alternating Mega Flash
Alternating Ultra Flash
Alternating Single Flash / Alternating Quad Flash
Alternating Single Flash / Alternating High Intensity Single Flash
Simultaneous Single Flash
Simultaneous Double Flash
NO.
Flash Patterns
13
14
15
16
17
18
19
20
21
22
23
Simultaneous Quad Flash
Simultaneous Quint Flash
Simultaneous Mega Flash
Simultaneous Ultra Flash
Simultaneous 8 Single Flashes / 4 Quad Flashes
Simultaneous 8 Single Flashes / 6 Fast Single Flashes
Left Side Steady & Right Side Single Flash
Simultaneous Single Flash (2Hz)
Simultaneous Double Flash (2Hz) [
SAE Class 1
]
Simultaneous Triple Flash (2Hz)
Simultaneous Quad Flash (2Hz)
Suggested Switch Connection
E-2215A / E-2215AC
Bracket Mount
E-2215AM / E-2215ACM
Magnetic Mount
NOTE: Disassembling lamp or cutting the wires voids the warranty
Switch #
Lamp Function
Switch 1
Power, Pattern Selection
& Synchronization
Operation:
Switch Part No.
ST307
(OFF-ON-Momentary ON)
Ground
Power
Pattern Selection
& Synchronization
From Battery Positive
Vehicle Ground
Blac
k
Red
Jumper Wires
Yello
w