QUICK MANUAL (RO30G, RO30C, RO60S)

• 

The RO unit should not be shut down 

for more than 7 days.

• 

If the system is shut down for longer, 

it has to be maintained.

• 

Nevertheless, the device should not 

be exposed to frost, 

because the membrane is protected 

only externally. 

1.  Bridge the resin cartridge.
2.  Unscrew the filter cup in the pre-filter 

group and remove the filter element. 

3.  Insert the feed pipe in the black filter. 

Transverse hole must be at the bottom.

4.  Fill the maintenance fluid into the right 

filter cup and firmly attach it again.

5.  Connect the system to the water supply. 

Both water outputs must remain open. 

Make sure the system is switched off!

6.  Open the water inlet valve and allow the 

inflowing water to flow freely through the 

system (No power!)

7.  Make sure that the water inlet valve 

does not remain open for more than 10 

seconds. There is a risk that the entire 

maintenance fluid will be completely 

flushed out.

To protect the membrane, proceed as follows:

1.  Disconnect the water supply if  

connected.

2.  Connect the concentrate hose so that  

excess water can drain.

3.  Disconnect the exit hose from the  

pre-filter case.

4.  Put the hose into the bottle of the  

maintenance fluid.

5.  Place the bottle securely.
6.  Start the pump. 
7.  The bottle is now quickly sucked  

empty.

8.  As soon as the bottle is empty,  

stop the system 

9.  Re-connect the hose to the  

pre-filter case.

Re-commissioning:

1.  Disconnect the concentrate and  

 

the hose from the bottom of the    

DI filter.

2.  Lead the hoses into a bucket.
3.  Connect the tab water line.

• 

Start the Pump at the control box. 

• 

Press the 

 buttons until you read  

FIL in the display. 

• 

The pump flushes the membrane.

4.  Now the water is flushed into the bucket. 

Let it run for at least 30 minutes to  

asure that no maintenance fluid is in 

the system. Reconnect the hose to the 

system like in picture 1.

HiFlo RO30G, RO30C, RO60S

HydroPower RO XXL (Trailer)

RO-PURE WATER FILTER SYSTEM

Membrane Protection