www.ungerglobal.com
UNGER Germany GmbH
Piepersberg 44
D-42653 Solingen
GERMANY
Tel.: (49) 212 2207 0
Fax: (49) 212 2207 222
[email protected]
UNGER UK Ltd.
9 Planetary Ind. Est.
Willenhall, WV13 3XA
UNITED KINGDOM
Tel.: (44) 01902 306633
Fax: (44) 01902 306644
[email protected]
Facebook “f” Logo
CMYK / .eps
Facebook “f” Logo
CMYK / .eps
15436
1 l
1
PROTECT YOUR RO-FILTER
•
Remember to maintain your
RO-Filter when it is not in use,
right now when it is stored in
winter.
•
Simple and quickly done with
the RO-Membrane
Maintenance.
To protect the membrane, proceed as follows:
1. Switch off the HydroPower RO and
disconnect the power supply.
2. Drain the water from the HydroPower RO.
Unscrew all filter top caps and open the
pressure relief valve on the back of the
HydroPower RO until no more water leaks
out.
3. Close the pressure relief valve and screw
the yellow cap onto the concentrate outlet.
4. Remove the pre-filter and resin filter
cartridges and store them protected from
dust and dirt.
5. Pour one bottle of membrane care liquid (1l)
into each of the mebrane tanks.
6. Fill all tanks (#1 pre- both
membranes #2, #3) with tap water until all
three tanks have filled just below the top
edge. Tank #4 can remain without water.
7. Close all four tanks.
The membranes are protected and the
HydroPower RO can be stored.
Never expose your RO unit
to frost!
NOTE:
The RO-Membrane Maintenance fluid #15436
is only a maintenance fluid, no anti-freeze!
HydroPower RO40C
RO-PURE WATER FILTER SYSTEM
Membrane Protection
RO-MEMBRANE MAINTENANCE
Part No.
Content
Pack
The membrane achieves its optimal life
with regular water flow or flushing.
If the HydroPower RO is not in use for an
extended period of time (longer than 7
days), the membrane must be protected
against blockage.
For this purpose, there is the UNGER
Membrane Care Agent (Order No. 15436).
You need one bottle (1l) for each memb-
rane. This preserves the current state of
the membrane and prevents reduced per-
formance and/or damage after sitting for
a longer period of time. Alternatively, you
can run the unit once a week for approx.
30 minutes to rinse the membranes.
Re-commissioning:
1. Unscrew all 4 filter top caps.
2. Drain the water: Unscrew the yellow cap and
assemble the concentrate hose.
Now open the pressure relief valve at the rear.
3. Insert the filters. Pay attention to the correct position (see page 33).
4. Screw the top-caps back on and start the system.
5. The membrane care liquid is automatically rinsed out and the resin
filter is protected by the by-pass process.
No responsibility accepted for accuracy;
subject to change without notice.