[Unex] - Ver. 1.9 20100907 P. 4
Pin Assignment:
55
GROUND
Ground
Digital ground
56
PAR
BiDir, Weak pull up
PCI bus parity
57
AD[17]
BiDir,, Weak pull down
PCI address/data bus bit 17
58
AD[18]
BiDir,, Weak pull down
PCI address/data bus bit 18
59
C/BE[2]#
BiDir, Weak pull up
PCI bus commands and byte 2 enables
60
AD[16]
BiDir,, Weak pull down
PCI address/data bus bit 16
61
IRDY#
BiDir,, Weak pull up
PCI initiator ready
62
GROUND
Ground
Digital ground
63
3.3V
Power
3.3V±10%
64
FRAME#
BiDir,, Weak pull down
PCI frame.
65
CLKRUN#
Input, Weak pull up
Control signal for PCI clock
66
TRDY#
BiDir,, Weak pull up
PCI target ready
67
SERR#
BiDir,, Weak pull up
PCI system error
68
STOP#
BiDir,, Weak pull up
PCI cycle stop signal
69
GROUND
Ground
Digital ground
70
3.3V
Power
3.3V±10%
71
PERR#
BiDir, Weak pull up
PCI bus parity
72
DEVSEL#
BiDir, Weak pull up
PCI device select
73
C/BE[1]#
BiDir, Weak pull down
PCI bus commands and byte 1 enables
74
GROUND
Ground
Digital ground
75
AD[14]
BiDir, Weak pull down
PCI address/data bus bit 14
76
AD[15]
BiDir, Weak pull down
PCI address/data bus bit 15
77
GROUND
Ground
Digital ground
78
AD[13]
BiDir, Weak pull down
PCI address/data bus bit 13
79
AD[12]
BiDir, Weak pull down
PCI address/data bus bit 12
80
AD[11]
BiDir, Weak pull down
PCI address/data bus bit 11
81
AD[10]
BiDir, Weak pull down
PCI address/data bus bit 10
82
GROUND
Ground
Digital ground
83
GROUND
Ground
Digital ground
84
AD[09]
BiDir, Weak pull down
PCI address/data bus bit 9
85
AD[08]
BiDir, Weak pull down
PCI address/data bus bit 8
86
C/BE[0]#
BiDir, Weak pull up
PCI bus commands and byte 0 enables
87
AD[07]
BiDir, Weak pull down
PCI address/data bus bit 7
88
3.3V
Power
3.3V±10%
89
3.3V
Power
3.3V±10%
90
AD[06]
BiDir, Weak pull down
PCI address/data bus bit 6
91
AD[05]
BiDir, Weak pull down
PCI address/data bus bit 5
92
AD[04]
BiDir, Weak pull down
PCI address/data bus bit 4
93
RESERVED
NC
Reserved
94
AD[02]
BiDir, Weak pull down
PCI address/data bus bit 2
95
AD[03]
BiDir, Weak pull down
PCI address/data bus bit 3
96
AD[00]
BiDir, Weak pull down
PCI address/data bus bit 0
97
5V
5V
Optional 5V for 5Ghz and 2.4Ghz PA
98
RESERVED_WIP4
NC
Reserved
99
AD[01]
BiDir, Weak pull down
PCI address/data bus bit
100
RESERVED_WIP4
NC
Reserved
101
GROUND
Ground
Digital ground
102
GROUND
Ground
Digital ground
103
AC_SYNC
NC
No use
104
M66EN
NC
PCI 66MHz Enable, no use
105
AC_SDATA_IN
NC
No use
106
AC_SDATA_OUT
NC
No use
107
AC_BIT_CLK
NC
No use
108
AC_CODEC_ID0#
NC
No use
109
AC_CODEC_ID1#
NC
No use
110
AC_RESET#
NC
No use