Underwriters Laboratories S600 Series User Manual Download Page 5

 

2-2. Electrical Performance

 

Specification 

Model No. 

Item  

S600-112 S600-124 S600-148 S600-212  S600-224 S600-248

Continuous Output Power 

600W 

Maximum Output Power (3Min.) 

680W 

Surge Rating 

800W 

Input 

voltage 

12V 24V 48V 12V 24V 48V 

Output Voltage 

100 / 110 / 120V     +/- 3% 

220 / 230 / 240V     +/- 3% 

Frequency 

(Switch Selections) 

50 / 60Hz     +/-  0.05% 

Efficiency 

(full 

load) 

87.0% 90.0% 92.0% 90.0% 93.0% 94.0% 

No Load Current Draw 

0.87A 

0.43A 

0.23A 

0.83A 

0.43A 

0.22A 

Output Waveform 

Pure Sine Wave  ( THD < 3% ) 

Output voltage Regulation 

100 / 110 / 120V RMS -10%/+4% 220 / 230 / 240V RMS -10%/+4%

Input Voltage Regulation 

10.5-15 

VDC 

21.0-30 

VDC 

42-60 

VDC 

10.5-15 

VDC 

21.0-30 

VDC 

42-60 

VDC 

Input Level Indicator 

Load Level Indicator 

Red / Orange / Green     LED 

Failure Indicator 

Red LED 

Protection 

Overload, Short Circuit, Reverse Polarity (Fuse),  

Over / Under Input Voltage, Over Temperature. 

Safety Certification 

UL458 

EN60950-1 

EMC FCC 

Class 

  EN50081-1: 1992 
  EN50082-1: 1992 
  EN55022B: 1994 
  EN61000-4-2: 1995 
  EN61000-4-3: 1996 
  ENV50204: 1995 

e-mark 

e13-020866

Operating Temperature Range 

0 - 33 

 

0 - 40 

 

Storage Temperature Range 

-30

 to 70

 

Cooling  

Loading controlled cooling fan 

Dimensions 

295(L) x 180(w) x 72(H) mm / 11.61(L) x 7.09(W) x 2.83(H) Inch

Weight 

2.7 kgs.     /     5.4 Lbs. 

 

 

Note: The specifications are subject to change without notice.

 

3

Summary of Contents for S600 Series

Page 1: ...S600 S600R Series Pure Sine Wave Inverter User s Manual...

Page 2: ...ting 10 11 3 5 AC Safety Grounding 12 13 3 6 DC Wiring Connections 13 14 3 7 Inverter Operation 15 4 Troubleshooting 16 5 Maintenance 17 6 Warranty 17 7 Appendices 18 7 1 CE LVD EN60950 1 Declaration...

Page 3: ...do not put batteries flammable materials or anything should be ignition protected around the inverter 1 2 Precautions When Working with Batteries 1 2 1 If battery acid contacts your skin or clothing...

Page 4: ...cations 2 1 1 Power tools circular saws drills grinders sanders buffers weed and hedge trimmers air compressors etc 2 1 2 Office equipment computers printers monitors facsimile machines and scanners e...

Page 5: ...RMS 10 4 Input Voltage Regulation 10 5 15 VDC 21 0 30 VDC 42 60 VDC 10 5 15 VDC 21 0 30 VDC 42 60 VDC Input Level Indicator Load Level Indicator Red Orange Green LED Failure Indicator Red LED Protecti...

Page 6: ...2 3 Mechanical Drawing 4...

Page 7: ...l 3 1 Front Panel Operation 3 1 1 Front view P U R E S IN E W A V E IN V E R T E R 3 1 2 ON OFF switch Leave the switch in the down position OFF during installation 3 1 3 Input Level Display Input Vol...

Page 8: ...580W Red Blink Over 580W 3 1 5 Failure Display failure status OVP over voltage protection UVP under voltage protection OTP over temperature protection OLP over load protection 3 1 6 AC outlet Outlet...

Page 9: ...ate the inverter with Remote ON OFF switch ON OFF switch on the Front Panel should be off 3 2 1 2 Ensure the remote control contact is off 3 2 1 3 Use 14 20 AWG wire to connect the Rear Panel Terminal...

Page 10: ...battery or other 12V 24V 48V power source represents positive and represents negative Reverse polarity connection will blow the internal fuse and may damage the inverter permanently 3 2 4 Use wire 8...

Page 11: ...m of the unit are not obstructed 3 3 5 Dust free Do not install the Inverter in dusty environment The dust can be inhaled into the unit when the cooling fan is working 3 3 6 Close to batteries Avoid e...

Page 12: ...inverter The red terminal represents positive and black terminal represents negative Insert the cables into the terminals and clamp the nuts and the wires securely WARNING You may observe a spark whe...

Page 13: ...switch to the ON position and the buzzer will send out beep sound at the moment the inverter will make self diagnosis and the LED s indicators will also appear various colors Finally the buzzer will s...

Page 14: ...such as inverters and generators which have their neutral conductors tied to ground in the same way as the neutral conductors from the utility tied to ground at the AC breaker panel For models configu...

Page 15: ...t to ground Electrical shock hazard may occur 3 6 DC Wiring Connections Follow this procedure to connect the battery cables to the DC input terminals on the Inverter The cables should be as short as p...

Page 16: ...cables for optimum inverter performance apply both 120V and 230V versions Model No Wire AWG Inline Fuse S600 112 4 100A S600 212 4 100A S600 124 6 50A S600 224 6 50A Also use only high quality copper...

Page 17: ...t one time 3 7 1 Controls and indicators The ON OFF switch turns the control circuit in the power inverter on and off It does not disconnect power from the power inverter The Inverter operates from an...

Page 18: ...anual Load LED bar flash Overload Reduce load No output voltage Low input voltage Recharge battery Voltage indicator check connections In the lower red zone and cables No output voltage Thermal shutdo...

Page 19: ...product against defects in materials and workmanship for a period of 24 months from the date of purchase and will repair or replace any defective power inverters if you directly returned them to us wi...

Page 20: ...7 1 CE LVD EN60950 Declaration of Conformity 18...

Page 21: ...7 2 FCC Class B Declaration of Conformity 19...

Page 22: ...7 3 e mark e13 020866 Declaration of Conformity 20...

Page 23: ...7 3 e mark e13 020866 Declaration of Conformity 21...

Page 24: ...7 4 UL UL458 Notice of Completion 22...

Reviews: