Summary of Contents for FCV 5G

Page 1: ...UNAOHM S r l Via G di Vittorio 49 20068 Peschiera Borromeo MI Italy Tel 39 02 36577787 Fax 39 02 51650195 Web www unaohm it E mail sales unaohm it ...

Page 2: ...ONVERTER 5 4 TECHNICAL DATA 6 4 1 SUPPLIED ACCESSORIES 7 5 WARRANTY 8 UNAOHM S r l reserves the right to make changes to the described product at any time for technical or commercial reasons as well as for compliance with legal requirements in the various countries For this reason the information contained in this manual may not be up to date ...

Page 3: ... Do not use the unit without the relative locks The instrument is intended for use in covered areas Therefore do not expose it to rain or dripping Do not use the unit in an explosive atmosphere constituted by flammable gases vapours smoke and powders The instrument can be used in overvoltage Category IIa and pollution grade 2 Do not switch on the unit immediately after moving it from a very cold r...

Page 4: ...y by qualified personnel or by personnel with basic electro technical and electrical safety knowledge For the units equipped with a battery remember the notes included in section 1 1 Use suitable measures to prevent the accumulation of electrostatic charges Do not touch circuits inside the unit without first applying the dedicated antistatic bracelet To clean the external parts Use soft cloths and...

Page 5: ...s which are not present continuously if the Field Meter is equipped with a Max Hold function it is possible to observe these as well these types of signals are otherwise impossible to measure given their temporal inconsistency The converted carrier will be displayed in IF SAT band that is in the frequency range between 1000 MHz and 2000 MHz The size and weight are very small while the power betwee...

Page 6: ...ich are discontinuous over time it is necessary to use the Max Hold function with which some of our Field Meters are equipped That said the following is the sequence of operations for using the converter 1 Connect an antenna able to receive the desired frequencies to the RF IN converter input 2 Connect a coaxial cable from the output of the RF OUT converter to the RF BNC input of the Field Meter 3...

Page 7: ...pression Output connector BNC Transfer Type Conversion of single SAT bands Down Converter Gain 0 dB 3 dB Gain Stability 0 1 dB C 5 40 C Noise figure 15 dBm Rejection of interferences 20dBµV without input 39 dB Carrier with single input carrier of 10dBm Rejection of input filter 45 dB 3000 Mhz Characteristics of the oscillator Frequency 2000 MHz Precision 1 MHz Power supply characteristics With DC ...

Page 8: ...ating temp From 5 C to 40 C Rel operating humidity 80 for temperatures up to 31 C with linear reduction up to 50 at 40 C Max operating altitude 2000 m Non operating temp From 10 C to 60 C Non operating humidity Max 95 Mechanical characteristics Dimensions H x L x T 150 x 90 x 25 mm Weight 0 25 kg with bag Finishing The unit is supplied in a nylon bag with an accessories compartment ...

Page 9: ...condition as long as it is economically convenient The availability of mechanical and electronic spare parts is guaranteed for up to 5 years when the circuits are manufactured with discreet components In the event integrated circuits are used the supply of spare parts is ensured while supplies last and subject to their availability on the global market The repair of instruments which are no longer...