Full product range & more information:
www.lumenalights.com
INSTALLATION:
IMPORTANT: Cable should be laid inside armoured conduit or piping to protect from water-logging, chemicals
found in soil and damage. If buried, it should be buried to at least 0.5m below ground to reduce damage risk. If
this method is not used, cable warranty will be void.
This bollard should be securely fixed to a concrete base, brick, paving slab or quality wooden decking. It should not be installed
directly into soil.
1.
Remove internal mounting base from the bollard body by removing the 3 x
socket screws.
2.
Drill out the 3 mounting holes using a 6mm masonry drill bit and insert the
plastic wall plugs (supplied).
3.
Locate and remove the connection block from inside the tube and insert the
cable into the waterproof junction box, as well as the mains cable.
4.
Strip back the 3 inner wires of the mains power cable to reveal the Live
(brown), Earth (yellow & green) and Neutral (blue).
5.
Insert the wires into the correct terminals of the terminal block, ensuring the
two brown Live wires (L) are connected to one another, the two blue
Neutral wires (N) are connected to one another and the two yellow and
green Earth wires are connected to one another
–
See diagram.
6.
Fully tighten the terminal block screws to clamp the wires down, ensuring
they make a connection to the conductor, not the rubber sheath.
7.
Once the wiring is complete, ensure the junction box is sealed / fully water
right, and return back inside the post.
8.
Insert the stainless steel bolts through the mounting plate and secure in place
(adjust base as required
–
see below).
9.
Replace the tube over the base and fasten the 3 x socket screws to secure.
ADJUSTABLE MOUNTING BASE:
The Pathos 316 incorporates a unique adjustable mounting base plate which enables installation
on uneven surfaces.
1.
Loosen the socket screws on the mounting base with the allen key provided.
2.
Loosely secure the base to the surface as per above.
3.
Using a spirit level, adjust the socket screws accordingly to level off the base.
4.
Fully tighten the mounting screws to complete installation.
LAMP INSTALLATION / REPLACEMENT:
(Ensure power is turned off prior to changing the lamp)
1.
Unscrew the head to reveal bulb holder.
2.
Remove / Insert lamp (screw base
–
E27).
3.
Replace head and turn until head becomes secure on the fitting.
IMPORTANT:
Condensation can occur due to the warmth inside the fitting produced by the lamp and the cold air outside. If
this is noticed, on a dry day, turn off the power supply, safely remove the head, and wipe dry with a soft cloth. It is
recommended to change lamps / install on a warm, dry day.
Light
Fitting
N
L
Live
Cables
Earth
Cable
Mains
Power
Cable
Neutral
Cables
Earth Cable
CABLES:
Neutral (N) = Blue
Live (L) = Brown
Earth = Yellow & Green
Colours of wire sleeving may vary
slightly
–
Test prior to use.