INSTALLATION:

  

 

 

Select a suitable mounting position where the sensor will be exposed to sunlight and not effected by other 
artificial lighting. 

 

Remove the lid (pull off). A small flat head screwdriver can be used to lever the lid off via the small screw 
driver cut out on each edge. 

 

Remove all components from the junction box and decide which self-sealing inlets you will use for your input 
and output cables. Pierce carefully with a screwdriver. Alternatively, the rubber inlets can be popped out and 
cable glands used. 

 

Mount  the  junction  box  in  position  via  the  two  mounting  holes  in  the  centre  of  the  junction  box,  using 
screws / rawl plugs relevant to the material you wish to mount to e.g. brick or wood. 

 

SELF SEALING INLETS: Push the input / output cables through the pierced inlets. 
CABLE GLANDS: Remove locking nut. Push cable gland through the entry hole and secure in place with the 
locking nut on the inside of the box. Push through the cable so that a sufficient amount is pulled through for 
wiring  (the  domed  clamp  may  need  to  be  loosened  beforehand  depending  on  the  diameter  of  the  cable. 
NOTE:  only  2  cable  glands  are  included.  For  additional  connections,  the  self-sealing  inlets  will  suffice,  or 
more glands can be purchased to increase IP Rating (recommended). 

 

Wire the photocell to the input cable and output cable(s) via the terminal block as per the diagram below. 
When making connections, ensure the terminals are tightened securely onto the stripped conductors and 
not the insulation cover, and that no loose strands of wire protrude. If cable glands are used, tighten the 
domed clamp to hold the cable in place securely. 

 

 

WIRING DIAGRAM:

 

 
 

PHOTOCELL CABLES 

 

Neutral (N) 

 Blue 

Live Out (X) - Red 
Live In (L) 

 Brown 

 

Photocell

  

N

 

X

 

L

 

 

Fitting 

Output Cable 

Mains  

Input Cable 

*Colour of wire sleeving may vary from mains supply 

**Terminal block may look different to the diagram 

***Location of photocell in box may vary 