Umbrella Mesh Network Umbra Legacy User Manual Download Page 1

 

1

 

User Guide

 

Umbra Legacy

 

Umbrella Mesh Network, LLC

 

         510 W. Amador Ave., Las Cruces, NM  88005

 

(855) 602

-

5276  

Ben@umbrellameshnetwork.com

 

Summary of Contents for Umbra Legacy

Page 1: ...1 User Guide Umbra Legacy Umbrella Mesh Network LLC 510 W Amador Ave Las Cruces NM 88005 855 602 5276 Ben umbrellameshnetwork com...

Page 2: ...Keypad 8 Enroll Delete Wireless Detector 9 Enroll Delete RFID Prox Tag Card 10 Enroll Delete Wireless Siren 11 Factory Default 12 Zone Type Reference Table 13 Umbra Legacy User guide Brought to you by...

Page 3: ...tanding and some programming of the Umbra Legacy panel The Quick Guide is available from www umbrellameshnetwork com and should be used for daily use Full interactive control requires a WiFi connectio...

Page 4: ...Amador Ave Las Cruces NM 88005 855 602 5276 Ben umbrellameshnetwork com Light on Light off Fast flashing Slow flashing AC power Battery power Panelor detector battery low power Away arm disarming Home...

Page 5: ...is to be used when there will be no one in the property and with all doors and windows closed Home Arm Press and hold for 3 seconds to activate Home arm function This function is to be used when ther...

Page 6: ...e user via an audible prompt of the reaction of the panel to certain functions These are listed below 1 Short Di Enrollment of wireless accessory was successful Arm Correct operation 1 Long Di Enrollm...

Page 7: ...mbrella Mesh Network LLC 510 W Amador Ave Las Cruces NM 88005 855 602 5276 Ben umbrellameshnetwork com Caution The following pages are instructions for adding and removing devices Device changes shoul...

Page 8: ...y will flash E1 if the slot is availa ble If the slot is not available the display will show E1 steady To enroll a keyfob or keypad into this slot if it is available trigger the device To enrol a keyf...

Page 9: ...ots The display will flash 01 if the slot is available If the slot is not available the display will show 01 steady To enroll a wireless detector into this slot if it is available trigger the device T...

Page 10: ...y will flash F1 if the slot is available If the slot is not available the display will show F1 steady To enroll a RFID Prox Tag Card into this slot if it is available present device to proximity area...

Page 11: ...e Siren slot The display will flash S1 if the slot is available If the slot is not available the dis play will show S1 steady To enroll a RFID Prox Tag Card into this slot if it is available trigger t...

Page 12: ...om Factory Default With the Umbra Legacy panel fully powered down apply power via the 12V DC port on the back while holding together the Enroll button and the SOS Button together for a full 15 seconds...

Page 13: ...yes no Burglar Interior alarm Interior Motion no yes yes no Perimeter Perimeter alarm Peremeter Doors no yes yes no Fire 24 hour Smoke Smoke Heat no yes yes yes Gas 24 hour Environmental CO Water Leak...