![Umarex Laserliner AutoCross-Laser 2 XP Operating Instructions Manual Download Page 16](http://html1.mh-extra.com/html/umarex/laserliner-autocross-laser-2-xp/laserliner-autocross-laser-2-xp_operating-instructions-manual_3550118016.webp)
16
B
C
2,5 m
<
1 mm = OK
GB
Technical data
(Subject to technical alterations 04.16)
Self-levelling range
±
3°
Precision
±
2 mm / 10 m
Laser wavelength linelaser (red)
635 nm
Laser wavelength linelaser (green)
510 nm
Laser wavelength point laser (red)
635 nm
Laser class
2 / < 1 mW
Power supply
4
x
1.5 V alkaline batteries
Operating time ACL 2 XP / ACL 2 XPG
approx. 10 h / approx. 3.5 h
Operating temperature
0°C ... + 45°C
Storage temperature
-10°C ... + 70°C
Protection class
IP 54
Weight (incl. batteries)
550 g
Dimensions (W x H x D)
130 x 105 x 70 mm
Checking the vertical line:
Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5 m
length on the wall, making sure that the bob can swing freely. Switch on the
device and align the vertical laser to the plumb line. The precision is within the
specified tolerance if the deviation between the laser line and the plumb line is
not greater than ± 1 mm.
Checking the horizontal line:
Position the device about 5 m from a wall and
switch on the cross laser. Mark point B on the
wall. Turn the laser cross approx. 2.5 m to the
right and mark point C. Check whether the
horizontal line from point C is level with point B
to within ± 1 mm. Repeat the process by turning
the laser to the left.
Regularly check the adjustment before use, after transport and after
extended periods of storage.
!