0.3 Safety 

Cautions 

!

 

DANGER 

  If the vacuum pump is used to pump toxic gas, the pump oil will be toxic, not to 

mention oil mist trap itself. Take care in maintenance. 

!

 

WARNING 

  Do not use the oil mist trap in an explosive atmosphere. Injury or fire can result. 

!

 

WARNING 

  Always use the oil mist trap at below the maximum flow rate. Otherwise, the internal 

pressure will rise and the oil mist trap will fail. The maximum flow rate is 120 L/min for 

the OMT-100A and 240 L/min for the OMT-200A. 

!

 

WARNING 

  Do not use the oil mist trap for inflammable gas. Injury or fire can result. 

!

 

WARNING 

  Do not touch or replace an element during vacuum pump operation or immediately 

after the pump is shut down. It is very hot and can cause burn. 

!

 

WARNING 

  Do not plug the exhaust port nor attach a device that interferes with the passage of gas 

to the exhaust port when the unit is operated. The pressure in the oil mist trap will rise 

and the unit may be damaged or fail. Note that the unit is not explosion-proof. 

!

 

CAUTION 

  If the oil mist trap is damaged, immediately turn off the switch for the vacuum pump 

and remove the power plug. If a damaged oil mist trap is used, oil mist may come out or 

internal pressure may rise. For safety, contact your local distributor. 

!

 

CAUTION 

  Do not use the oil mist trap for corrosive gas. Damage or failure can result. 

 

 

-02- 

!

 

CAUTION 

  Do not modify the oil mist trap.    If modified, troubles of the oil mist trap will not be 

covered by warranty.    Also it can generate oil mist or cause internal pressure rise. 

 

0.4 

Receipt and Storage of Oil Mist Trap 

0.4.1 

Receipt of oil mist trap 

Every care has been taken before shipping the oil mist trap, but check the following 

after unpacking it. 

(1)  Is the unit the correct mode you ordered? 

(2)  Are the prescribed accessories (O-ring P-41) supplied? 

(3)  Is any part damaged in transit? 

(4)  Is any part off position? 

If any problem is found, contact your local ULVAC KIKO representative. 

0.4.2 

Storage, installation and environmental conditions during operation 

Meet the following conditions during storage, installation and operation. 

(1)  Ambient temperature during operation 

:  7°C to 40°C 

(2)  Surface temperature during operation 

:  Cannot be used at   

  

 

above 

80°C 

(3)  Others (during storage and operation) 

a) 

To be free from corrosive or explosive gas 

b) 

Not to be condensing dew on the oil mist trap 

c) 

To be free from dust and dirt 

d) To 

be 

indoors 

e) 

Do not turn the oil mist trap sideways. 

f) 

Do not expose to direct sunlight. 

g) 

To be away from heat source 

h) Not 

dry 

atmosphere 

 

(Store the unit at a relative humidity of 10% or more.) 

!

 

NOTE 

  Do not give impact to the oil mist trap.    Damage or failure can result. 

 
 

-03- 

Summary of Contents for OMT-100A

Page 1: ...fully read this manual and fully understand the specifications operating procedure and safety cautions NOTE No part of this manual may be reproduced for use by a third party without written consent by...

Page 2: ...tact your local distributor CAUTION Do not use the oil mist trap for corrosive gas Damage or failure can result 02 CAUTION Do not modify the oil mist trap If modified troubles of the oil mist trap wil...

Page 3: ...s and preventive actions 1 1 1 DANGER Hazardous gas hazardous material Hazard Preventive actions You may be injured by contact with pump oil that has been turned toxic in the oil mist trap or with tox...

Page 4: ...e that interferes with the passage of a gas connected to the exhaust port The internal pressure of the oil mist trap will rise and the unit may be damaged or fail This unit is not explosion proof NOTE...

Page 5: ...s 5 INSPECTION AND MAINTENANCE 5 1 Maintenance Check the following once a day during operation 1 Oil leak in the connection with the vacuum pump 2 Oil mist or oil gushing out from the case 3 Unusual s...

Page 6: ...ause for more than 30 minutes replace the element Scheduled replacement is recommended according to the element replacement frequency in Table 4 DANGER If the vacuum pump is used to pump toxic gas pum...

Page 7: ...rate of oil mist trap 5 The check valve is not functioning properly 5 Repair or clean the check valve Oil is not recovered into the pump case 1 The pump is running continuously at a high suction press...

Page 8: ...Malfunctions caused by special atmospheric conditions such as salt damage inflammable c Malfunctions caused by usage conditions that differ from those stated in the user manual performance specificat...