30
10.10.
Installing the Sensor Unit and Sensor Head
To install the sensor head, reverse the procedure for removing the sensor unit and
sensor head in Section 2.
The sensor head and sensor unit are connected with the pin of the sensor head anode
(indicated with arrow in Fig. 10-10).
Install the sensor head slowly and make sure that its terminal has been inserted into
the connector of the circuit board. The sensor head should turn without resistance if it is
inserted correctly. If it is inserted correctly, the sensor head should fit into the depth of
the SC1 circuit. Fix it with screws.
Fig. 10-24 Installing the sensor unit and sensor head
10.11.
Maintenance
Depending on the usage, the electrode section may be worn out until cleaning up cannot
cope with the problem. In that event, replace parts with new ones.
Fig. 10-25 shows the maintenance kit. Here, one set of cathode is made up of magnetic
pole 1, magnetic pole 2 and spacer.
Fig. 10-25 Maintenance kit
Anode
Cathode
Magnetic pole 1
Spacer
Magnetic pole 2
A
Caution the screw