UltraView PCIEXT64U User Manual Download Page 3

User Manual ~ 

UNIVERSAL PCI BUS EXTENDER

   

Model   PCIEXT64U and PCIEXT64UB

 

1/18/2007-

 REV F

     

COPYRIGHT  C  2007 

 

ULTRAVIEW CORP.        (925) 253-2960   www.ultraviewcorp.com 

 

ON 

 

 
 

Power Limit Switch:

 

 

The POWER LIMIT switch allows selection of  a power 
limit  value  of  15,  25  or  35  watts.  For  example,  if  set  to 
25W, the PCIEXT64U or UB will limit the +3.3V, +5V 
and  VIO  current  if  the  UUT  draws  more  than  25  watts 
total on its +3.3V, +5V and VIO power pins.   

Note that 

the  35  W  setting  is  above  the  maximum  per-slot 
power (25 W) allowed by the PCI specification.  Also, 
the +/-12V power is not protected from overloads. 

 

 

Current Measurement Test Points:

 

 
The  PCIEXT64U  and  UB  allow  real-time  measurement 
of  power  consumption  during  board  operation.    A 

volt

meter or scope can be connected with its “+” lead to 

either  the  5I,  3.3I  or  VIO  white  test  points,  and  its  “-“ 
lead to the black GND test point.  The voltage output on 
these 

test 

points 

has 

1:1 

Volt-to-Ampere 

correspondence.  Hence,  a reading of 2.4V on the 5I test 
point  indicates  that  the  UUT  is  drawing  2.4 

amperes

 

from the 5V supply. 
 

Live (Hot) Insertion:

 

The  Live  Insertion  capability  is  enabled  by  first  saving 
the UUT’s configuration register contents, using the live 
insertion  software  provided,  and  then  switching  the  Slot 
Power  switch  off,  which  removes  power  and  isolates  all 
signals to the connector of the UUT.  
 
With  the  Slot  Power  switch  off,  a  user  can  then  remove 
or insert the UUT, or insert a new UUT of the same type, 
without the need to power the host system off.  The plug-
in  UUT  may  be  modified  or  swapped  without  powering 
down the host system.    
 
Then,  with  the  replaced  UUT  (of  same  type  as  old) 
installed, the slot power switch may be turned on again.    
 
Switching  on  Slot  Power  will  require  the  UUT 
configuration  register  contents  to  be  reinitialized  to 
operate  correctly,  again  using  the  live  insertion software 
provided,  as  described  in  the  section  “Live  Insertion 
Software”  These  configuration  registers  need  to  be 
initialized prior to re-accessing the board. 
 

Summary of Contents for PCIEXT64U

Page 1: ...tender With software for Windows XP 2000 ME 98 95 User Manual REV F 1 18 07 TABLE OF CONTENTS INTRODUCTION 2 FEATURES 2 LIVE HOT INSERTION 3 INSTALLING THE PCIEXT64U OR PCIEXT64UB INTO A SYSTEM 4 EXTERNAL POWER OPTIONAL AND RISKY 5 LIVE INSERTION SOFTWARE FOR WINDOWS 3 1 95 98 ME 2000 AND XP TM 6 LIMITED WARRANTY 8 WARNING EMPLOY ESD PROTECTION MEASURES AT ALL TIMES WHEN USING A BUS EXTENDER TO PR...

Page 2: ...tion FEATURES General 5 Volt 3 3V and VIO Power LEDs 32 or 64 Bit PCI Slot and UUT capacity PCIEXT64UB Usable in 5V or 3 3V PCI bus slots and with Universal 5 3 3V or 5V only boards under test UUTs PCIEXT64U Usable in 5V or 3 3V PCI bus slots and with Universal 5V only or 3 3V only UUTs Slot Power ON OFF switch Bus Switches Power Monitoring Test Points 3 Volt 5 Volt and VIO Current Probe Points Ov...

Page 3: ...nts has a 1 1 Volt to Ampere correspondence Hence a reading of 2 4V on the 5I test point indicates that the UUT is drawing 2 4 amperes from the 5V supply Live Hot Insertion The Live Insertion capability is enabled by first saving the UUT s configuration register contents using the live insertion software provided and then switching the Slot Power switch off which removes power and isolates all sig...

Page 4: ...p BIOS configuration space and registers will not be loaded or automatically performed on insertion of a new UUT unless you use the supplied live insertion software to reload the UUT s configuration space as described in the manual section Live Insertion Software DO NOT INSTALL THE 12V and 12V ENABLE JUMPERS ON THE PCIEXT64U UB UNLESS YOUR UUT REQUIRES 12V VERY FEW PCI BOARDS DO This will greatly ...

Page 5: ...ly is connected to power points Special care must be taken with an external power supply as power provided to the plug in UUT is not current limited Also if the external 5V and 3V if used are below 4 75V and 2 7V respectively the bus switches will not turn on and the UUT will not be accessible to the system While the use of an external power supply is valuable for voltage margin testing of UUTs it...

Page 6: ...nd restoring them in a new UUT Once you have clicked on the small window for your UUT this window should appear on top of other windows Open your UUT s window to expose all registers by dragging its lower right corner downwards You will see the contents of your UUT s first 16 configuration registers A description of each register s function is contained in the PCI Local Bus Specification although ...

Page 7: ...he contents of these registers We just save the contents of these registers so that we can power off and remove the UUT and then later restore these contents when inserting a new UUT of the same type as the one removed on the PCIEXT64U or UB Saving a UUT s configuration registers and restoring them into a new UUT Once you are in the correct window entitled Edit PCI Configuration Space for your UUT...

Page 8: ...ry the PCIEXT64U or UB in a different system 3 System resets or hangs when Configuration registers are written to by live insertion software Some boards under test use CPLDs or FPGAs that fail to initialize correctly due to the controlled slew power ramping on the PCIEXTU UB Limited Warranty Ultraview Corporation hardware products are warranted against defects in materials and workmanship for a pe...

Page 9: ...User Manual UNIVERSAL PCI BUS EXTENDER Model PCIEXT64U and PCIEXT64UB 1 18 2007 REV F COPYRIGHT C 2007 ULTRAVIEW CORP 925 253 2960 www ultraviewcorp com ...