Ultratec TWISTER X Operator'S Manual Download Page 7

Exterior

The casing of the Twister X is steel with a powder paint coating. To clean simply wash with mild soap and warm 
water. 

Ensure the power is disconnected when cleaning!!!

Maintenance Procedure

Troubleshooting

NOT POWERING UP:

1) Check that power switch is in ON position on and illuminated. 
2) Check power cord is securely inserted and locked into Fused Power Entry Module and connected to an        
     appropriate power source.
3) Verify that the supplied voltage is correct for the fans setup.  
4) Check that the appropriate fuse has not failed.
5) Contact Ultratec Special Effects Service Department.   
     . 

FAN NOT TURNING:  
 
1) Check that DMX address is set to correct address being used.
2) Verify that Valid DMX LED is ON solid confirming good DMX signal. 
3) Verify that correct DMX address is being sent to unit from DMX console.
4) Check that fan blades are not full of dust / debris.  Clean fan blades (Ensure unit is disconnected from any    
     power source).
5) Look for visual damage to fan blades / motor.
6) Contact Ultratec Special Effects Service Department.

The fan can be controlled locally by using higher numbers in the DMX display.
700-799 will give focused beam/forward fan speed settings of 0-99 which equates to OFF to 100% full on.
800-899 will give wide beam/reverse fan speed settings of 0-99 which equates to OFF to 100% full on.

Note:

 Stand Alone Operation overrides DMX

Stand Alone Operation

Note:

 The hidden / visible DMX display setting only applies to the valid DMX address ranges. When the unit is     

           in the Stand-Alone modes (700 - 800 ranges) the display will continuously stay visible regardless of which 
           display mode it is set to.

5

www.ultratecfx.com

Summary of Contents for TWISTER X

Page 1: ...v 032021 Operators Manual...

Page 2: ...ons 1 Technical Speci cations 2 Technical Drawings 2 Twister X Setup 3 Twister X DMX Operating Procedure 4 RDM 4 Twister X Stand Alone Operation Procedure 5 Maintenance 5 Troubleshooting 5 Warranty 6...

Page 3: ...pervised by suitably trained and authorized personnel 2 Do not modify the machine or use a machine which has been damaged in any way 3 Allow su cient air circulation around the machine at all times 4...

Page 4: ...ing Hanging Frame Truss Mountable 1500 CFM Performance Wide pattern or focused pattern outputs to achieve very directional ow Externally accessible fuses Selectable DMX Display Visibility Visible Stea...

Page 5: ...g power up will switch to DMX visible mode To return hidden hold the ones s button during power up NOTE Unit will retain the last display setting at next power up NOTE The hidden visible DMX display s...

Page 6: ...0 100 is wide beam ow reverse 1 Set desired DMX address on the digital display using the arrow keys between 001 to 511 Note If the unit is in the native hidden display mode The display goes to sleep w...

Page 7: ...ing good DMX signal 3 Verify that correct DMX address is being sent to unit from DMX console 4 Check that fan blades are not full of dust debris Clean fan blades Ensure unit is disconnected from any p...

Page 8: ...ler Upon completion of the repair Ultratec Special Effects will return the unit via the most economical means available Should you require the item express returned the user dealer is responsible for...

Page 9: ...Effects GmbH Dieselstrasse 30 40 60314 Frankfurt am Main Germany Direct 49 69 87 000 1850 Fax 49 69 87 000 1899 Canadian Shipping Address For All Canadian Repairs Ultratec Special Effects 1960 Blue He...

Reviews: