Operating Procedure

1.  The fog machine must be connected to a sine wave voltage supply of 20 Amps free of electrical interference.
2.  Open a 4 Litre (1 Gallon) container of Ultratec Special Effects fog fluid and insert the fluid pickup tube into the spout 

of the fluid container.

3.  Turn ON the Power switch located on the rear panel. The Power switch will illuminate to indicate the presence of 

power.

4.  After approximately 9 minutes, the fog machine will be fully heated and ready for full output. 
5.  Set the demand from 1 to 100% using the built-in remote control or through a DMX control network.

Digital Remote Control

Valid DMX 
Light

DMX In

DMX Out

LSG Receptacle 
(2 amps)

On/Off Switch

Fog On/Off

Value Down (-)

Value Up (+)

Cycle 
Menus

Toggle LCD 
Brightness

Diagnostics Screen Button  
Press “Menu” to exit

(For Service Technician)

Write to Memory

When variables are changed on 
the digital remote they are written 
to memory after 60 seconds or 
when you change screens. The 
secondary displays return to the 
main menu if inactive for 60 
seconds.

Summary of Contents for G3000

Page 1: ...G3000 Fog Effects Generator Operator s Manual www ultratecfx com VER 22 10 14...

Page 2: ...ical Drawings 4 Operating Procedure 5 Digital Remote Control 5 G3000 Screen Shots 7 DMX Operation 9 Other Features 9 Remote Extension 9 Fluid Level Detection 9 Maintenance 9 Exterior 9 Heat exchanger...

Page 3: ...case 3 Persons suffering from asthma or allergenic sensitivity may experience irritation discomfort or allergic symptoms when exposed to fog effects 4 Ensure that this unit is grounded at all times Fa...

Page 4: ...t CLF 3004 G3000 Fog Machine 220 240 Volt w Industrial Option CLF 3006 G3000 Fog Machine 220 240 Volt w Air Option CLF 3007 G3000 Fog Machine 120 Volt w Show Control CLF 3008 G3000 Fog Machine 105 Vol...

Page 5: ...er approximately 9 minutes the fog machine will be fully heated and ready for full output 5 Set the demand from 1 to 100 using the built in remote control or through a DMX control network Digital Remo...

Page 6: ...PRE FOG TIME 0 00 mm ss DMX Address 511 Data 0 D 1 0 Set the desired time for the fog machine to run using the or buttons 0 10 Minutes Set the desired time for the fog machine to stop using the or bu...

Page 7: ...on Note error from trying to turn on machine that is not yet hot enough Machine on with remote Not fully heated see temp bar and H is on so requesting 100 but getting 27 Machine on with DMX Machine wa...

Page 8: ...output stops when fluid gets low F indicator on main screen If set the Fog output stops when fluid gets low F indicator on main screen Power up starting use not recommended Code versions for remote ou...

Page 9: ...at the remote port left of the remote control While pressing pull the remote out of the dock and attach the cord Fluid Level Detection The G3000 is manufactured with an Electronic Fluid Level Detecti...

Page 10: ...Dissipates 2x the rate of Quick Dissipating Fog Fluid while maintaing similar characteristics Molecular Fog Fluid A faster dissipation versus the Director s Choice Fog Fluid This thick clean white fo...

Page 11: ...y is based on destination of the original sale Any additional costs incurred are the responsibility of the Dealer and or the customer Abuse or poor maintenance is not accepted Proof of purchase or pro...

Reviews: