background image

Maintenance

Exterior

The casing of the PFI9D is stainless steel with a powder paint coating. To clean simply wash with mild soap 
and warm water.

Using high quality Ultratec Special Effects fluid should result in a long heat exchanger life. 

See Power Fog Industrial 9D Rapid Change Technology Replacement Guide R-A manual on how to change 
out copper tube.

Heat Exchanger

6

www.ultratecfx.com

DMX Operation

The Power Fogger Industrial 9D is equipped with DMX-RDM controls as a standard feature. 2 channels of 
DMX are required. 

                               The base address = Fog Output Control. 
                               The base a 1 = Eclipse aux. port control.

1.Plug in the Power Fogger Industrial 9D and switch the Main Power ON to warm it up (Solid green LED on   
   back of machine).

2.Apply a DMX signal to the DMX IN 5 pin connector on the rear of the unit. A terminator may be required 
   on   the DMX OUT connector in some applications.

                                Base DMX= Fog rate controlled 0-100%
                                DMX+1=Eclipse power on above 50%
                                DMX+2= Air on above 50%

3.Select a valid DMX address with the arrow keys to set the base address of the fogger. 
            

Note: 

 The display goes to sleep when not in use. Touching any key once wakens it. 

  
The set DMX address controls the fog flow rate from 1-100%. The next consecutive address turns on the 
auxiliary port if it is set over 50% for control of an Eclipse. Also 

            Note:

 If the air option is present, 3 consecutive DMX addresses will be required.

.4.The red valid DMX LED is on solid if good DMX signal is present. 
    DMX control will override hand remote only while active.
    Slow or irregular flashing indicates poor DMX data 

RDM Functions 

                     RDM features will allow remote identify by flashing the 
                     DMX display, DMX address changing and machine 
                     temperature monitoring. As well the machine's group 
                     and manufacturer identification data is available.

Remote

DMX In

DMX Out

DMX

Address

Green LED = Heating Status

Red LED = DMX Status

Summary of Contents for 9D

Page 1: ...v 112020 Power Fog Industrial 9D PFI9D Operators Manual ...

Page 2: ...re w Air Option 3 Options 4 Optional Show Control Remote Operations 4 Show Control Remote LED Indicator 4 Show Control Operation 4 Optional Timer Duration Remote Operations 5 Timer Duration Remote LED Indicator 5 DMX Operation 6 Maintenance 6 Exterior 6 Heat Exchanger 6 Troubleshooting 7 Recommended Fluid 8 Maintenance Fluid 8 Warranty 9 Contact Information 10 Note Please read entire manual before...

Page 3: ...d Water Based Fog generating system Water Base Fog Technology Water Base Fog technology is achieved by pumping a glycol water mixture through a heat exchanger This will vaporize the fluid as it passes through the processing block The vaporization of the fluid forces the hot mixture through the output nozzle When mixed with ambient air it forms an opaque aerosol fog The fog is made up of tiny droplet...

Page 4: ...F 4461 Power Fog Industrial 9D PFI 9D 220 240 Volt CLF 4457 Power Fog Industrial 9D PFI 9D 220 240 Volt w Air Option Power Rating 120 Volt A C 50 60 Hz 13 Amps 220 240 Volt A C 50 60 Hz 8 5 Amps Fluid Water Base Fog Fluid Use only Ultratec Fluid PFI Technical Specifications Technical Drawings Power Fogger Industrial 9D 18 73 11 14 6 55 6 02 1 2 www ultratecfx com ...

Page 5: ... approximately 9 minutes the fog machine will be fully heated and is ready for full output the indicator will be on solid 6 It may be necessary to prime fluid into the system to expel any air The Variflow control on the remote handset should be set to the full position A dry hose can take between 45 60 seconds to prime This only needs to be done if the unit was left to run dry NOTE In order to prime...

Page 6: ... the fog only one set of contacts that close for the entire fogging cue For Show Control Operation the DMX Address must be set on 555 Closing the Show Control Remote terminals with dry contacts triggers the following machine functions C 1 Fog On Off w Variflow C 2 ECLIPSE On C 3 Air Option Show Control Operation 4 www ultratecfx com Options Remotes The Show Control Remote and Timer Duration Remote a...

Page 7: ...our local Ultratec Special Effects dealer Variflow Sets the desired fog output rate from 0 to full output Duration Sets fog on time from 0 4 25 minutes when using the timer settings Interval Sets fog off time from 0 4 25 minutes when using the timer settings The interval time must be set to 0 to disable the timer operation Note To operate the Eclipse Low Fog Generator using the Timer Duration Remote ...

Page 8: ...uired on the DMX OUT connector in some applications Base DMX Fog rate controlled 0 100 DMX 1 Eclipse power on above 50 DMX 2 Air on above 50 3 Select a valid DMX address with the arrow keys to set the base address of the fogger Note The display goes to sleep when not in use Touching any key once wakens it The set DMX address controls the fog flow rate from 1 100 The next consecutive address turns o...

Page 9: ... in jug 2 Ensure fluid pickup line is fully primed with fluid 3 Ensure that green heater status LED is ON solid indicating that unit is fully heated 4 If using DMX control ensure that DMX address on 9D is set between 001 to 511 range 5 If using DMX control ensure that red Valid DMX LED is ON solid and that correct DMX channel on the DMX console matches DMX address set on the 9D 6 If using hand held ...

Page 10: ...ns or effects that require quick dissipation of fog It produces excellent steam effects that re semble nitrogen bursts and it also keeps low lying fog from rising too quickly when it is used with theEclipse Low Fog Generator or LSX Extra Quick Dissipating Fog Fluid Dissipates 2x the rate of Quick Dissipating Fog Fluid while maintaing similar characteristics Molecular Fog Fluid A faster dissipation v...

Page 11: ...Effects will return the unit via the most economical means available Should you require the item express returned the user dealer is responsible for indicating this request and for any difference in freight cost Warranty will be voided and customer will lose all rights guaranteed by the warranty if any of the following are observed occur If any non Ultratec Special Effects fluid is used at any poi...

Page 12: ...mbH Dieselstrasse 30 40 60314 Frankfurt am Main Germany Direct 49 69 87 000 1850 Fax 49 69 87 000 1899 Canadian Shipping Address For All Canadian Repairs Ultratec Special Effects 1960 Blue Heron Drive London Ontario N6H 5L9 USA Shipping Address For All USA Repairs Ultratec Special Effects 640 Gadson Street Groveland Florida 34736 Contact Us www ultratecfx com 10 www ultratecfx com ...