![ULTRASOURCE 320601-E Owner'S Manual Download Page 14](http://html1.mh-extra.com/html/ultrasource/320601-e/320601-e_owners-manual_3512502014.webp)
S T A R T U P
UltraSource LLC
1414 West 29th Street
Kansas City, MO 64108-3604
Phone: (816) 753-2150 • Fax: (816) 753-4976
[email protected] • UltraSourceUSA.com
Part Number
320601-E
P A G E 6
Installation
1. Place the smoke producer in position on the control side of the Grand Prize™ 3
smokehouse. Connect the smoke inlet pipes between the smoke producer and the
smokehouse after both units have been leveled.
2. Connect a cold water supply line (¼-in. copper) to the fire safety solenoid valve on the
side of the smoke producer.
3. Connect power cord provided with smoke producer to AC receptacle (120-volt, 15 amps).
4. If smokehouse is equipped with a CookMaster™ microprocessor control, connect control
wires provided with unit to the smoke producer as shown in SCHEMATICS Page 16.
5. The smoke producer is equipped with a cycle timer that operates the auger drive motor
intermittently. The timer is preset at the factory for approximately 20% on and 80% off
(refer to OPERATION Page 11). This percentage can be adjusted to increase or decrease
smoke production. See timer instructions on OPERATION Page 11.
6. The small blower mounted on the side of the smoke producer has an air inlet cover
plate. This
cover plate must be opened approximately half way
when the smoke
producer is in operation. If the cover plate is kept closed, it will result in poor circulation
of smoke within the cabinet and there will be excessive leakage around the seams of the
smoke producer itself.
7.
The safety switch is factory set – do not adjust.