Ultranatura GP-100 Original Operating Instructions Download Page 11

n

A built-in thermostat protects the motor from
overloading and blocking. The pump is switched
off automatically by the thermostat if overheating
occurs and is switched on again automatically
after cooling.

6. Operation

n

Install the equipment on a solid and level
surface.

n

Fill the pump housing with water via the water
filler screw (4). Filling the intake line accelerates
the intake process.

n

Open the discharge line.

n

Connect the mains cable. The intake process
starts automatically; water can be suctioned in
for up to 5 minutes (maximum suction height). 

n

If the pump is removed again after use, it must 
always be refilled with water whenever it is 
connected up and used again.

7. Replacing the power cable

Danger!

If the power cable for this equipment is damaged, it
must be replaced by the manufacturer or its after-
sales service or similarly trained personnel to avoid
danger.

8. Cleaning, maintenance and

ordering of spare parts

The equipment is almost completely maintenance
free. In order to ensure a long service life, however,
we recommend that you regularly check and care for
the product.

Danger!

The equipment must be disconnected from the
power supply (pull the power plug) prior to
performing any maintenance.

8.1 Servicing

n

If the equipment becomes clogged, connect the
discharge line to the water line and disconnect
the suction hose. Open the water line. Switch on
the equipment several times for approx.
two seconds. This should resolve the majority of
clog-related problems.

n

Replacing the mains cable: 

Disconnect the

equipment from the power supply! 
A defective mains cable may only be replaced

by a qualified electrician.

n

There are no parts inside the equipment which 
require additional maintenance.

8.2 Storage

n

If the pump is not going to be used for a long
time or has to be removed for the winter months,
rinse it out with water, empty it completely and
allow it to dry.

n

The equipment must be completely drained
before it is subjected to frost.

n

After long stoppages, make sure the rotor turns 
correctly by briefly switching the pump on and
off.

8.3 Ordering replacement parts:

Please quote the following data when ordering
replacement parts:

n

Type of machine

n

Article number of the machine

n

Identification number of the machine

n

Replacement part number of the part required

For our latest prices and information please go to
www.isc-gmbh.info

9. Disposal and recycling

The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.

11

GB

Anleitung_GP_100_SPK7__  24.02.14  15:40  Seite 11

Summary of Contents for GP-100

Page 1: ...sanleitung Gartenpumpe t Original operating Instructions Garden Pump p Mode d emploi d origine Pompe de jardin Art Nr 200100000401 EH Art Nr 41 801 43 I Nr 11014 GP 100 Anleitung_GP_100_SPK7__ 24 02 1...

Page 2: ...esen und beachten Danger Read and follow the operating instructions and safety information before using for the first time Danger Avant la mise en service lisez le mode d emploi et les consignes de s...

Page 3: ...1 1 4 3 2 3 Anleitung_GP_100_SPK7__ 24 02 14 15 40 Seite 3...

Page 4: ...Sie das Ger t ausschlie lich entsprechend dem in dieser Gebrauchsanweisung angegebenen Verwendungszweck n Sie sind f r die Sicherheit im Arbeitsbereich verantwortlich n Sollte das Kabel oder der Stec...

Page 5: ...echnische Daten Netzanschluss 230V 50 Hz Aufnahmeleistung 800 Watt F rdermenge max 3000 l h F rderh he max 36 m F rderdruck max 0 36 MPa 3 6 bar Ansaugh he max 8 m Druck und Sauganschluss ca 33 3 mm R...

Page 6: ...er Netzanschlussleitung Gefahr Wenn die Netzanschlussleitung dieses Ger tes be sch digt wird muss sie durch den Hersteller oder seinen Kundendienst oder eine hnlich qualifizierte Person ersetzt werden...

Page 7: ...t somit wieder verwendbar oder kann dem Rohstoffkreislauf zur ckgef hrt werden Das Ger t und dessen Zubeh r bestehen aus verschiedenen Materialien wie z B Metall und Kunststoffe F hren Sie defekte Bau...

Page 8: ...mpengeh use f llen Dichtigkeit der Saugleitung berpr fen Saugventil reinigen Saugkorb reinigen Saugh he berpr fen F rdermenge ungen gend Saugh he zu hoch Saugkorb verschmutzt Wasserspiegel sinkt rasch...

Page 9: ...ctions n You are responsible for safety in the work area n If the cable or plug is damaged by external influences the cable may not be repaired The cable must be replaced by a new one This work may on...

Page 10: ...ods and unnecessary damage to the pump as a result of stones and solid foreign bodies n Screw an intake hose min ca 32 mm 11 4 plastic hose with spiral reinforcement either directly or with a threaded...

Page 11: ...ne and disconnect the suction hose Open the water line Switch on the equipment several times for approx two seconds This should resolve the majority of clog related problems n Replacing the mains cabl...

Page 12: ...into intake Make sure intake line is close Clean intake valve Clean strainer Check suction height Inadequate delivery rate Suction height too high Strainer dirty Water level falling rapidly Pump perf...

Page 13: ...xclusivement dans le respect de l application conforme indiqu e dans ce mode d emploi n C est vous qui tes responsable de la s curit dans la zone de travail n Si le c ble ou le connecteur est endommag...

Page 14: ...50 Hz Puissance absorb e 800 Watt Refoulement maxi 3000 l h Hauteur manom trique maxi 36 m Pression de refoulement maxi 0 36 MPa 3 6 bar Hauteur d aspiration maxi 8 m Raccord de pression et d aspirati...

Page 15: ...i la ligne de raccordement r seau de cet appareil est endommag e il faut la faire remplacer par le producteur ou son service apr s vente ou par une personne de qualification semblable afin d viter tou...

Page 16: ...eurement ou tre r introduit dans le circuit des mati res premi res L appareil et ses accessoires sont en mat riaux divers comme par ex des m taux et mati res plastiques Eliminez les composants d fectu...

Page 17: ...nch it de la conduite d aspiration Nettoyer la soupape d aspiration Nettoyer le panier d aspiration V rifier la hauteur d aspiration D bit insuffisant Hauteur d aspiration trop lev e Panier d aspirati...

Page 18: ...H paskaidro du atbilst bu ES direkt vai un standartiem G apib dina atitikim EU reikalavimams ir prek s normoms Q declar urm toarea conformitate conform directivei UE i normelor pentru articolul z B p...

Page 19: ...ces As an alternative to returning the electrical device the owner is obliged to cooperate in ensuring that the device is properly recycled if ownership is relinquished This can also be done by handin...

Page 20: ...reproduction by any other means in whole or in part of documentation and papers accompanying products is permitted only with the express consent of ISC GmbH La r impression ou une autre reproduction d...

Page 21: ...21 Technische nderungen vorbehalten Technical changes subject to change Sous r serve de modifications Anleitung_GP_100_SPK7__ 24 02 14 15 40 Seite 21...

Page 22: ...22 Anleitung_GP_100_SPK7__ 24 02 14 15 40 Seite 22...

Page 23: ...23 Anleitung_GP_100_SPK7__ 24 02 14 15 40 Seite 23...

Page 24: ...EH 03 2014 01 Anleitung_GP_100_SPK7__ 24 02 14 15 40 Seite 24...

Reviews: