ver.1.1
3
w
w
w
.ul
tral
u
x.bg
3
w
w
w
.ul
tral
u
x.bg
•
Remote control RF code learning from receiver
1.
Turn off the power supply of the receiver.
2.
Press and hold
“
2
”
key for 5 seconds until indicator of remote controller turns off.
3.
Turn on the power supply of the receiver. Indicator of the remote controller flashes three times
after successful code learning.
Note:
The distance from drivers/dimers to remote controllers should be less than 2 meters.
•
Restoring factory settings of remote controller
1.
Press and hold “
2
”
key for 20 seconds until indicator of remote controller turns on.
2.
Press
“
6
”
button. Indicator of the remote controller flashes three times after successful operation.
TAKING CARE OF THE NATURAL ENVIRONMENT CLEANLINESS
•
The product and its components are not harmful to the environment
•
Please dispose the package elements separately in containers for the corresponding material.
•
Please dispose the broken product separately in containers for out of usage electrical
equipment.