2-3

A 48” cable assembly, part number 517565-2020, is available for connection

from the MUX-05 to a COE unit.  This cable has the DIN connector from the

MUX-05 installed on one end.

Cable Assembly 517565-2020

MUX-05

DIN CONNECTOR

WIRE COLOR

COE INPUT

Pin 1, TX-

BLK

-

Pin 2, TX+

RED

+

2.1.3

JPD-101 Controller

If a JPD-101 Controller is connected to a COE unit, the JPD-101 must be

plugged into a DIA-01 Control Interface Adapter.  Then the DIA-01 is

connected to the COE unit.

DIA-01

to

COE Input

TX+ Black

to

+

TX- Red

to

-

2.1.4

CCU-100 or CCU-100/A Central Control Unit

The CCU-100 Central Control Unit has two control outputs on channels 4

and 7.  Each control output channel could be connected to a COE unit to

increase the number of domes from 20 to up to 250.

CCU-100 (CHS 4 & 7)

to

COE Input

Pin 1, TX-

to

-

Pin 2, TX+

to

+

Pin 3, GND

to

S

Summary of Contents for COE-16

Page 1: ...COE 08 COE 16 CONTROL OUTPUT EXPANDER USER S MANUAL Manual Number 517872 1960 Ultrak Inc 4465 Coonpath Road NW Carroll OH 43112 740 756 9222 800 443 6680 FAX 740 756 4237 ...

Page 2: ...222 800 443 6681 TECHNICAL SUPPORT ALL RIGHTS RESERVED NO PART OF THIS PUBLICATION MAY BE REPRODUCED BY ANY MEANS WITHOUT WRITTEN PERMISSION FROM ULTRAK INCORPORATED THE INFORMATION IN THIS PUBLICATION IS BELIEVED TO BE ACCURATE IN ALL RESPECTS HOWEVER ULTRAK INCORPORATED CANNOT ASSUME RESPONSIBILITY FOR ANY CONSEQUENCES RESULTING FROM THE USE THEREOF THE INFORMATION CONTAINED HEREIN IS SUBJECT TO...

Page 3: ...be followed by any number of alphanumeric characters Joystick Controller JPD 100 JPD 101 JPD 200 may be followed by any number of alphanumeric characters Small System Interface SSI 100 may be followed by any number of alphanumeric characters Control Output Expander COE 08 COE 16 may be followed by any number of alphanumeric characters Control Receiver CRX 610 BX CRX 801AX CRX 801BX Standard EN6006...

Page 4: ...nd to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful...

Page 5: ...ed for ventilation and to ensure reliable operation of the unit and to protect it from overheating These openings must not be blocked or covered This unit should not be placed in a built in installation unless proper ventilation is provided or the manufacturer s instructions have been adhered to 10 Power Sources This unit should be operated only from the type of power source indicated on the marki...

Page 6: ...nly those controls that are covered by the operating instructions as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the unit to its normal operation e If the unit has been dropped or the cabinet has been damaged f When the unit exhibits a distinct change in performance this indicates a need for service 18 Rep...

Page 7: ...ser to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to presence of important operating and maintenance servicing instructions in the literature accompanying the equipment 220 240 Vac 50 Hz power cord...

Page 8: ...ROSTATIC SENSITIVE DEVICES WARNING ELECTROSTATIC SENSITIVE DEVICE USE PROPER CMOS MOSFET HANDLING PRECAUTIONS TO AVOID ELECTROSTATIC DISCHARGE NOTE Grounded wrist straps must be worn and proper ESD safety precautions observed when handling the electrostatic sensitive printed circuit boards ...

Page 9: ... Controller 2 3 2 1 4 CCU 100 or CCU 100 A Central Control Unit 2 3 2 1 5 CATS Family Video Switcher 2 4 2 1 6 COE 08 A or COE 16 A Control Output Expander Unit 2 6 2 1 7 FastScan SmartScan Units 2 6 2 2 INSTALLATION DRAWINGs 2 6 SECTION 3 OPERATION 3 1 3 1 controls and indicators 3 1 3 2 operatiON 3 2 SECTION 4 MAINTENANCE 4 1 4 1 PREVENTIVE MAINTENANCE 4 1 4 2 Troubleshooting 4 1 LIST OF FIGURES...

Page 10: ...t Rack Mount D N 517872 1440 2 7 Installation COE 16 R Control Output Expander Unit Rack Mount D N 517872 2440 2 8 Installation COE 08 D Control Output Expander Unit Desk Top D N 517872 3440 2 9 Installation COE 16 R Control Output Expander Unit Desk Top D N 517872 4440 2 10 ...

Page 11: ...3040 One Input to Eight Outputs Desk Top 110 120V COE 16 R 517872 2040 One Input to Sixteen Outputs Rack Mount 110 120V COE 16 D 517872 4040 One Input to Sixteen Outputs Desk Top 110 120V COE 08 R X 517872 5040 One Input to Eight Outputs Rack Mount 220 240V COE 08 D X 517872 7040 One Input to Eight Outputs Desk Top 220 240V COE 16 R X 517872 6040 One Input to Sixteen Outputs Rack Mount 220 240V CO...

Page 12: ...astScan SmartScan units as long as the combined cable distance from each output on the control output expander unit to the last dome in the chain is no more than 4000 feet 1 2 SPECIFICATIONS ELECTRICAL Power Requirements 110 120V 50 60 Hz 0 080A 220 240V 50 60 Hz 0 040A Fuse 120 Vac Power Input T 080 220 Vac Power Input T 040 Input One 4 Position Plug In Terminal Block Outputs COE 08 Two 12 Positi...

Page 13: ...ck Mounting holes accommodate 10 mounting screws Dimensions 1 72 H x 19 W x 10 51 D 44 4 mm H x 490 1 mm W x 266 9 mm D Weight 5 lb 2 3 kg Finish Front Panel Light gray Chassis Rear Panel Alodine 1200 ENVIRONMENTAL Operating Temperature 32 F to 122 F 0 C to 50 C Humidity Limits 0 to 95 non condensing ...

Page 14: ......

Page 15: ...CCU 100 Central Control Unit a CATS Video Switcher or another COE Control Output Expander Up to ten receivers can be daisy chain wired from each output The maximum distance to the last receiver in a chain is 4000 feet A 6 foot power cord with a NEMA 5 15P plug is supplied with the 110 120V unit This is a 3 wire grounding type plug This is a safety feature If you are unable to insert the plug into ...

Page 16: ...X Black to TX Red to 2 1 2 MUX 05 Multiplexer Up to five JAD 832 Controllers can be connected to a MUX 05 Multiplexer Four of the JAD 832 controllers must be plugged into a DIA 01 and then the DIA 01 s are connected to the inputs on rear panel of the MUX 05 One of the JAD 832 Controllers can be plugged directly into the front panel of the MUX 05 Then one of the MUX 05 outputs is connected to the C...

Page 17: ...D 101 Controller is connected to a COE unit the JPD 101 must be plugged into a DIA 01 Control Interface Adapter Then the DIA 01 is connected to the COE unit DIA 01 to COE Input TX Black to TX Red to 2 1 4 CCU 100 or CCU 100 A Central Control Unit The CCU 100 Central Control Unit has two control outputs on channels 4 and 7 Each control output channel could be connected to a COE unit to increase the...

Page 18: ...s the DIN connector from the MUX 05 installed on one end Cable Assembly 517565 2020 CCU 100 or CCU 100 A DIN CONNECTOR WIRE COLOR COE INPUT Pin 1 TX BLK Pin 2 TX RED 2 1 5 CATS Family Video Switcher The CATS Video Switchers have a communication connector COMM that supplies four communication ports to the domes Each communication port can control up to ten daisy chained domes as long as the maximum...

Page 19: ...r communication ports are not used Use the communication ports on the MUX 05 or the CCU 100 or CCU 100 A Video Switcher COMM Connector to COE Input Port 1 Pin 1 to Pin 2 to Pin 4 Gnd to S Port 2 Pin 7 to Pin 3 to Pin 5 GND to S Port 3 Pin 15 to Pin 11 to Pin 8 Gnd to S Port 4 Pin 16 to Pin 12 to Pin 9 Gnd to S ...

Page 20: ...artScan to FastScan or SmartScan to Pin 4 Data to Pin 4 Data to Pin 3 Data to Pin 3 Data S to Cable Shield to Cable Shield 2 2 INSTALLATION DRAWINGS The following drawings are provided for assistance during installation of the COE 08 A and COE 16 A Control Output Expander Units Title Page COE 08 R Active Control Output Expander Unit D N 517872 1440 2 7 COE 16 R Control Output Expander Unit Rack Mo...

Page 21: ...CONTROL OUTPUT EXPANDER 2 7 ...

Page 22: ...CONTROL OUTPUT EXPANDER 2 8 ...

Page 23: ...CONTROL OUTPUT EXPANDER 2 9 ...

Page 24: ...CONTROL OUTPUT EXPANDER 2 10 ...

Page 25: ...he unit is plugged into an AC outlet REAR VIEW 110VAC 220VAC VOLTAGE SELECTOR This selector sets the power input to 110 120V or 220 240V Use a small blade screwdriver to switch between 110Vac and 220Vac The fuse must match the power input selected A T 080A fuse is required for the 110 120V power input A T 040A fuse is required for 220 240V power input ...

Page 26: ...no operating procedures for this unit The control data is sent from the controller to any interface equipment such as the DIA 01 Control Interface Adapter CCU 100 Central Control Unit or Video Switcher and then to the Control Output Expander Unit The Control Output Expander Unit sends all control data out the output ports ...

Page 27: ...rform the following 1 Inspect all interface connecting cabling for deterioration or other damage 2 Clean the front panel with a soft cloth using any mild commercial cleaner 4 2 TROUBLESHOOTING If problems occur at the initial installation phase verify that the procedures in Section 2 have been performed correctly Because this unit is just one part of an overall system it may be necessary to verify...

Page 28: ...ABLE PARTS COMPRISING THE CONTROL OUTPUT EXPANDER UNIT REFER SERVICING TO QUALIFIED PERSONNEL ONLY Any equipment returned to Ultrak for warranty or service repair must have a prior written Authorization to Return Material ARM form completed for its repair Contact Ultrak Inc Service Department 4465 Coonpath Road Carroll Ohio 43112 740 756 9222 Toll Free U S A 1 800 443 6681 ...

Reviews: