background image

User Manual

Thank you for purchasing an Ultrahaptics STRATOS 
Inspire (USI). This manual provides an introduction to the 
evaluation kit, including set-up and how to access support 
from Ultrahaptics. The manual also includes Compliance, 
Health & Safety guidance and Warranty information. A 
separate 

Installation Template

 provides instructions for 

installing or mounting the STRATOS Inspire.

Please read and understand this documentation in full 
before installing or using the STRATOS Inspire. 

The STRATOS Inspire has been designed to project haptic 
sensations onto hands or fingertips using its array of 
ultrasound transducers. It is intended to be used in a static 
desktop mount or fixed installation.

Height

Width

Depth

Weight

Metric

188mm

430mm

54mm

3.1 kg

Imperial

½

’’

17’’

’'

7 lb

Power supply:

24V DC         +/- 10%, 3.75A Max. 
5mm x 2.1mm barrel connector
A Limited Power Source in accordance 
with IEC 62368-1:2014 must be used.

Data connection: 

USB Type-C connector

Ingress protection:

IP4X

Mounting methods:

VESA 100 × 100 mount; desktop stand

Haptic interaction zone:

50-700mm / 2” to 27 ½” deep from 
front of array grille

Hand tracking device:

Leap Motion

®

 camera module

Ultrasound transducers:

256

Construction:

Die cast and machined aluminium, 
stainless steel

Ambient operating 
temperature: 

0°C to +40°C / 32°F to 104°F

The STRATOS Inspire is certified compliant to 
IEC 62368-1:2014. 

The STRATOS Inspire has been assessed by Ultrahaptics 
to be compliant with environmental regulations including 
RoHS and REACH directives. All components used in the 
STRATOS Inspire have been confirmed as compliant with 
the relevant standard by their manufacturers. For more 
information, please contact Ultrahaptics.

WARNING:

 These warnings must always 

be followed to avoid risk of serious injury or 
damage.

Caution:

 Indicates precautions that must be 

followed to avoid discomfort for users, service 
interruption or device damage.

Electrical hazard: 

Indicates a potential hazard 

which may result in electric shock.

High sound pressure:

 Indicates a situation 

which may increase the risk of hearing 
damage.

Indicates information to assist in correct or 
optimal operation of the STRATOS Inspire.

We want you to enjoy using the STRATOS Inspire (USI) 
safely. Please read and understand the information below 
carefully to reduce the risk of electric shock, injury or 
damage to the evaluation kit or other property. 

We recommend that you carry out a risk assessment 
incorporating these precautions, local requirements and 
environmental factors before operating the STRATOS 
Inspire.

WARNING:

 If you have a pacemaker, 

implantable cardioverter defibrillator (ICD) 
or other medical device installed or if you 
are pregnant, elderly or suffer from a heart 
condition, hearing problems or other serious 
medical condition which could be affected by 
ultrasound or electromagnetic interference, 
consult a doctor before using the STRATOS 
Inspire.

WARNING:

 Always ensure that the STRATOS 

Inspire is securely and stably mounted before 
use. Always use the mounting points or 
desktop stand provided.

WARNING:

 Users must stop using the 

STRATOS Inspire immediately if they 

NOTE: 

Reviews: