background image

Models

ADA35

ASA35

ADA50

ADA70

ASA50

ASA70

AUA50

AUA70

ADA50-12

ADA70-12

ASA50-12

ASA70-12

AUA50-12

AUA70-12

Circle the model of your cooler and record
the serial number below.

Read Carefully All Of This Manual Before
Installing The Unit

Encierrre con un circulo el modelo de su
enfriador y escribe el número de série abajo.

Lea Con Cuidado Todo Este Manual Antes De
Instalar La Unidad

Serial #

Número De Série

Safety Rules

1. Read instructions carefully.
2. Electrical hook up should be done by a qualified electrician, so that

all electrical wiring will conform to your local standards.

3. Always turn 

OFF POWER

 and 

UNPLUG

 motor and pump inside

the cooler before installing or performing any maintenance.

4. Your cooler will run on either 120V or 240V A.C., single phase,

60 Hz (cycle) current.

5. Motor and pump have a grounded, molded plug and an automatic

thermal overload switch which will shut motor off when it overheats.
The motor will restart automatically when it cools down.

WARNING:

  To reduce the risk of fire or electric shock, do

not use this fan with any “solid-state fan speed control device.”

Read And Save These Instructions

Vea el Español en el interior.

110498

3-05

www.championcooler.com

Table Of Contents

Safety Instructions ....................................................................... 1
Operation ..................................................................................... 2
Installation Instructions ............................................................. 2-3
Electrical Wiring Diagram ............................................................ 3
Maintenance Section ................................................................ 3-4
Troubleshooting ............................................................................ 4
Warranty ..................................................................................... 5

Specification Tables 

(Tablas de Especificaciones) ....................

5

Parts List (ADA35,  ASA35) ................................................... 6-7
Parts List (ADA50,  ADA50-12,  ADA70,  ADA70-12) .......... 8-9
Parts List (ASA50,  ASA50-12,  ASA70,  ASA70-12) .......... 10-11
Parts List (AUA50,  AUA70,  AUA50-12,  AUA70-12) ...... 12-13

Instrucciones en Español ...................................................

13-16

Evaporative Cooling

Evaporative cooling is nature’s way of cooling.  When air is moved
over a wet surface, water is evaporated and heat is absorbed.  When
stepping out of swimming pool with the wind blowing, evaporative cooling
makes you feel cool, even though the air may be warm.

This unit works on the same principle.  Air is drawn across wet filter
pads where the air is cooled by evaporation and then circulated
throughout the building.  It is this combination of cooled air and the
movement of air over the skin which makes it feel cool.

Unlike refrigeration systems which recirculate the air, an evaporative
cooler continually brings in fresh air while exhausting old air.  You are
completely replacing the air every 2 to 4 minutes by opening windows
or doors or a combination of both.  The air is always fresh, not stale,
laden with smoke and odors as happens with refrigerated air
conditioning.

Owner’s Manual

Summary of Contents for ADA35

Page 1: ...r 110498 3 05 www championcooler com Table Of Contents Safety Instructions 1 Operation 2 Installation Instructions 2 3 ElectricalWiring Diagram 3 Maintenance Section 3 4 Troubleshooting 4 Warranty 5 Specification Tables Tablas de Especificaciones 5 Parts List ADA35 ASA35 6 7 Parts List ADA50 ADA50 12 ADA70 ADA70 12 8 9 Parts List ASA50 ASA50 12 ASA70 ASA70 12 10 11 Parts List AUA50 AUA70 AUA50 12 ...

Page 2: ...ck Hi Red Low White Com Green Ground Mount motor Install blower motor in the motor mount yokes adjusting the yoke if necessary Fasten with the pro vided mounting clips see Fig 2 NOTE Adjustable yoke will have to be reversed for 1 H P motors Install pulley Install the adjust able motor pulley so that it aligns with the blower drive pulley see Fig 3 and tighten set screw Electrical Installation WARN...

Page 3: ...rvoir Tighten screw 6 Slide float shield 8 up over float body 5 until it snaps into place working inside This should be done for your safety Adjust pulley to a larger diameter and readjust belt tension plug motor in install inspection panels and retest amperage draw Repeat this pro cess until correct amperage draw is attained Increasing motor pulley diam eter increases amperage draw Decreasing mot...

Page 4: ...ined you can get many years of efficient and satisfactory ser vice from your cooler In the event additional information is desired your dealer will be more than glad to assist you in every possible way Problem Possible Cause Remedy Failureto start or no airdelivery Inadequate airdelivery withcooler running Water drainingonto roof Musty or unpleasant odor 1 No electrical power to unit Fuseblown Cir...

Page 5: ...nty applies to original purchaser only Motor Specifications Especificaciones Del Motor General Specifications Especificaciones Generales Models Modelos Weight lbs Peso libras Cabinet Dimensions in Dimensiones De La Caja pulgadas Duct Opening in Abertura De Ducto pulgadas Dry Seco Operating Lleno Height Altura Width Anchura Depth Profundidad Width Anchura Height Altura ADA35 ASA35 120 169 22 9 16 3...

Page 6: ...ibutor Bracket Right Soporte Para El Distribuidor De Agua Derecha 222004 005 222004 005 24A Water Distributor Bracket Left Soporte Para El Distribuidor De Agua Izquierda 222004 003 222004 003 25 Evaporative Media Medio Evaporativo 110103 110103 26 Support Media Soporte Para El Medio Evaporativo 222130 027 222130 027 27 Water Reservoir Bandeja Acumuladora De Agua 281030 281030 28 Pump Mount Montura...

Page 7: ...498 Replacement Parts Piezas De Repuesto ADA35 ASA35 20 4 35 38 37 25 28 30 31 32 29 27 16 6 ADA35 23 24 21 40 10 26 22 39 34 14 13 11 12 24A 8 3 ASA35 6 ASA35 33 19 5 ADA35 3 ADA35 17 18 15 9 1 7 2 5 ASA35 ...

Page 8: ...ver Flow Assembly Montaje De Desagüe 3OA 1 3OA 1 3OA 1 3OA 1 28 Float Valve Flotador FL BK FL BK FL BK FL BK 29 Pump Assembly Bomba C60P 120 C60P 120 C60P 120 C60P 120 30 Tube Water Delivery Tubo De Agua 310716 310716 310716 310716 31 Bleed Off Kit Equipo De La Válvula De Desahogo 310586 310586 310586 310586 32 Receptacle Motor Toma De Corriente Del Motor 110393 110393 110393 110393 33 Receptacle ...

Page 9: ... 110498 Replacement Parts Piezas De Repuesto ADA50 ADA50 12 ADA70 ADA70 12 16 23 25 22 2 1 22 15 24 14 19 28 38 33 32 17 37 36 35 18 39 13 10 8 6 5 12 31 30 20 9 7 6 3 11 27 41 4 43 26 42 44 45 46 47 42A ...

Page 10: ...27 Over Flow Assembly Montaje De Desagüe 3OA 1 3OA 1 3OA 1 3OA 1 28 Float Valve Flotador FL BK FL BK FL BK FL BK 29 Pump Assembly Bomba C60P 120 C60P 120 C60P 120 C60P 120 30 Tube Water Delivery Tubo De Agua 310716 310716 310716 310716 31 Bleed Off Kit Equipo De La Válvula De Desahogo 310586 310586 310586 310586 32 Receptacle Motor Toma De Corriente Del Motor 110393 110393 110393 110393 33 Recepta...

Page 11: ... 110498 Replacement Parts Piezas De Repuesto ASA50 ASA50 12 ASA70 ASA70 12 46 22 7 27 45 44 31 30 41 6 9 38 17 32 22 42 26 36 35 3 4 29 20 43 28 19 6 5 12 11 8 10 14 24 15 23 16 25 33 37 39 18 2 1 47 42A ...

Page 12: ... Over Flow Assembly Montaje De Desagüe 3OA 1 3OA 1 3OA 1 3OA 1 28 Float Valve Flotador FL BK FL BK FL BK FL BK 29 Pump Assembly Bomba C60P 120 C60P 120 C60P 120 C60P 120 30 Tube Water Delivery Tubo De Agua 310716 310716 310716 310716 31 Bleed Off Kit Equipo De La Válvula De Desahogo 310586 310586 310586 310586 32 Receptacle Motor Toma De Corriente Del Motor 110393 110393 110393 110393 33 Receptacl...

Page 13: ...sitivo de estado sólido para controlar la velocidad del ventilador Enfriamiento Por Evaporación Este enfriador evaporativo funciona circulando el aire fresco Usted no tiene aire recirculado que esté viciado cargado de humo y olores como ocurre con los sistemas de aire acondicionado a base de refrigeración En cambio se reemplaza el aire completamente cada 2 a 4 minutos abrien do las puertas o las v...

Page 14: ...240V Vea las esquemas del cableado para las instalaciones de 120V y 240V IMPORTANTE Con un motor de una sola velocidad no use la línea roja en el cableado del enchufe y la clavija del motor Envuelva el extremo de ambas líneas rojas con cinta eléctrica PRECAUCIÓN Enchufe una bomba del enfriador evapora tivo solamente y nada más al receptáculo de la bomba ADVERTENCIA Compruebe que la caja del enfria...

Page 15: ...ecte la línea al flotador y apriete la tuerca hasta que no salga agua Afloje el tornillo 6 y ajuste la varilla 7 has ta que el nivel del agua esté a una altura de 1 pulgada por debajo del bor de superior de la bandeja Apriete el tornillo 6 Ponga la pantalla pro tectora del flotador 8 sobre el cuerpo del flotador hasta que se agarre AmperioYTensión De La Correa Esta unidad viene equipada de una pol...

Page 16: ...uando la unidad está funcionando Hace Ruido Motor se apaga y se enciende Enfriamiento inadecuado Demasiada humedad en la casa Olor a encerrado olor desagradable Garantía Limitada La presente garantía se extiende al comprador original de un enfriador evaporativo instalado y utilizado bajo condiciones normales No cubre daños ocurridos por accidente descuido o abuso por parte del propietario No autor...

Reviews: