CAUTION
This equipment is designed and sold for commercial use only by personnel trained and
experienced in its operation and is not sold for consumer use in and around the home nor for
use directly by the general public in food service locations. For equipment to be used by the
general public, please contact the factory.
INSTALLATION
The griddles are equipped for the voltage indicated on the nameplate mounted on the front
panel. They will operate on alternating current (AC) only.
WARNING
DO NOT CONNECT TO DIRECT CURRENT (DC).
The installation of the electric griddle should conform to the:
NATIONAL ELECTRIC CODE AND ALL LOCAL ELECTRIC CODES AND
ORDINANCES AND THE LOCAL ELECTRIC COMPANY RULES AND
REGULATIONS
For your protection we recommend that a qualified electrician install this griddle. He
should be familiar with electrical installations and all electric codes. Proper connections
and power supply are essential for efficient performance. The external wiring should be
in conduit or an approved type of flexible cable suitable for operation at the temperature
indicated on the wiring diagram, and of a proper size to carry the load. The supply circuit
should be properly fused and equipped with a means of disconnecting, as required by
local electrical code. THE BODY OF THE GRIDDLE SHOULD BE GROUNDED (DO NOT
GROUND TO A GAS SUPPLY LINE).
GENERAL OPERATING PROCEDURES
The Ultra-Max series electric griddles may be wired for operation in the field for either 1-phase
or -phase power supplies by making line connections at the junction box(es) located at the
rear of the unit. Models 724T-20/400V, 76T-20/400V & 748T-20/400V, should be wired for
-phase power supply only. Two junction boxes are provided on the 760T & 772T for making
line connections.
CONNECTING POWER SUPPLY
Detach cover on junction box at rear of unit. There is a terminal block for the supply connection
in the junction box. Wires can be rerouted in the terminal block for phase hook-up. See wiring
diagrams and model voltage on unit panel
LOCATING AND LEVELING THE UNIT
Do not install the unit closer than -inch from a side wall and/or closer than -inch from a rear
wall. Make sure the unit is properly ventilated. Level unit by adjusting the (4) feet which have
an adjustment of -/4” (4.75mm) for accurate leveling and perfect line-up with other Ultra-
Max series units.