![ULTIMATRON FRANCE SMART BMS Series Instructions For Use Manual Download Page 13](http://html1.mh-extra.com/html/ultimatron-france/smart-bms-series/smart-bms-series_instructions-for-use-manual_3375424013.webp)
3.1
Verification
After receiving the LiFePO4 battery, please check if the device has been dam-
aged in any way ( e. g . transportation) . In this case, please do not put the
device into operation and contact the seller.
3. 2
The
installation
conditions
As long as the battery holders are already available and suitable, they can
continue to be used. Make sure that the LiFePO4 battery is installed and fixed
so that it cannot move back and forth during use (tension the strap).
3.3
Debug
Due to variations in operating temperature and charge- discharge rate, the
cycle capacity may be diff erent from the nominal capacity. Do not disassem-
ble the battery without authorization from the supplier. Parallel and series are
acceptable. In parallel, it can accept 10 parallels. In series, it can accept up to 4
series. The series and parallel structure can accept up to 4S4P.
The operating temperature:
Discharge temperature: -20 ~ 60°C
Storage temperature: -5 ~ 35°C
Charge temperature:
The model with Heating film: -20 ~ 55°C
Standard model: 0 ~ 55°C
3.4
Protection
against
short
circuits
Single
battery
installation
The battery must be protected by a fuse.