background image

 

Issue 2: 17/08/2017  MILLBROOK INDUSTRIES LTD                                                                

 

 

Assembly and fitting  

 

 

Prior to installation, ensure your mattress elevator is suitable for your local 

supply, i.e. 230 Volts 50Hz and UK 3-pin socket (BS1363)   

  
1.

 

Ensure that the bed to which the Ultimate Healthcare mattress elevator is 

fitted has a base of suitable strength and rigidity to support the product.   

 

 

 

2.

 

Having removed the mattress from the bed, place the mattress elevator 

on the headboard end of the bed base with the chrome bars uppermost.  

 

 

3.

 

The end of the base frame should be placed approximately 80mm from 

the end of the bed.   

 

 

4.

 

The two chrome bars are adjustable; these need to be set to suit the 

width of mattress.  To do this, remove the four e-clips on the top and 

bottom bars of the mattress frame and extend to approximately 50mm 

inside the edge of the mattress.  This will ensure full support.  Once done 

so, replace the e-clips.  

 

 

5.

 

Note the Ultimate Healthcare mattress elevator has colour-matched 

retaining straps to identify where they should be fastened.  

 

 

6.

 

Secure the mattress elevator base section to the bed base using:  

• 

The single blue strap along the length and looped under the base.  

• 

The two green straps across the width and looped under the base.  

 

 

 

 

 

 

 

Following step 6, ensure straps are tensioned fully and the mattress elevator is 

retained firmly in place.  See picture below.  

 

 

Summary of Contents for UBEE0001-2

Page 1: ...Issue 2 17 08 2017 Mattress Elevator UBEE0001 2 Read instructions completely before using the Ultimate Healthcare mattress elevator User Manual...

Page 2: ......

Page 3: ...ng from 76cm to 152cm wide 2 6 to 5 Electrically powered the mattress elevator provides postural support allowing the user users to sit up unaided at the touch of a button The back angle adjustment is...

Page 4: ...ar DO keep body parts away from the mattress elevator s framework and moving parts DO unplug from the power socket when not in use DO use a bottom sheet and duvet Don ts DON T exceed the maximum user...

Page 5: ...nd of the bed 4 The two chrome bars are adjustable these need to be set to suit the width of mattress To do this remove the four e clips on the top and bottom bars of the mattress frame and extend to...

Page 6: ...e mattress with the bed sheet fitted onto the bed base and mattress elevator 8 Secure the mattress elevator upper section to the mattress using the single black strap around the width of the mattress...

Page 7: ...ains plug into the power socket Power on is indicated by a green light on the transformer 11 The mattress elevator is ready for use Instructions for use Using the hand controller press and hold the le...

Page 8: ...ess elevator is unplugged from the power supply Failure to do so could result in injury from electric shock Use a cleaner or disinfectant solution Remove the cleaner or disinfectant with clean water a...

Page 9: ...here is power to the mattress elevator this is indicated by a green light on the transformer 3 Check the power cables are all connected properly 4 If the mattress elevator is overloaded or usage excee...

Page 10: ...idths 76cm 152cm 2 6 5 Backrest angle variable 10 to 70 Maximum duty cycle 10 6 minutes usage per hour Mattress Elevator net weight 16kg Transformer Linak Power required 240v 50 60Hz Transformer outpu...

Page 11: ...Issue 2 17 08 2017 MILLBROOK INDUSTRIES LTD...

Page 12: ...Issue 2 17 08 2017 Ultimate Healthcare Calmore Industrial Estate Nutwood Way Totton Southampton Hampshire SO40 3WW Tel 0333 321 8996 Email info ultimatehealthcare co uk...