background image

24

•  aircleaner

1

2

3

Function and type of operation

Set up without castors

1

  Place the unit stand at the installa-

tion site.

2

  Carefully place the unit on the unit 

stand and lower it.

3

  Screw the grub screw into the nut 

using an Allen key to secure it.

The unit can rotate so it can be orientated to meet the respec-
tive requirements.

Do not rotate the unit more than 360°! Risk of damage to the 
power cord.

Danger of tipping!

Do not lean against the installed unit!

Summary of Contents for sasoo 2-00211

Page 1: ...sasoo aircleaner Operating instructions for the Article no 2 00211 IMPORTANT Read these instructions carefully before using your new aircleaner Retain the instructions for future use Status 02 2021...

Page 2: ......

Page 3: ...ng to fire hazards 10 Safety instructions for CRM substances 11 Safety at work 11 Residual risks 13 Unit components and technical data 15 Rating plate 15 Technical overview 16 Technical depiction 17 T...

Page 4: ...ions 30 Filter replacement 31 Change HEPA filter 32 Change activated carbon filter 34 Possible malfunctions 36 Replacement filter 37 Service 38 Notices on electronic device disposal 38 Contact 38 Atta...

Page 5: ...ons is deemed improper use and is therefore prohibited This document is used exclusively for the purpose of information and has no contractual character As part of improving the product and product cu...

Page 6: ...d other small particles in the nanoscale range are separated from the air at a separation efficiency of 99 995 The activated carbon filter removes odors from the purified air The clean respiratory air...

Page 7: ...on no account to be classified higher than personal responsibility and or local regulations During operation and in all other types of work on the sasoo the operating company is always responsible fo...

Page 8: ...of the system and the operating instructions Explosion hazard Do not extract any explosive concentra tions of gases vapors or dusts Health hazard No extraction of carcinogenic and or toxic gases vapor...

Page 9: ...tions carefully before starting erection and installation work Always make sure you observe the safety instructions included Take heed of the safety symbols for Mechanical hazard and electrical hazard...

Page 10: ...red hot chips or smoldering cigarettes to be sucked into the system Since the risk of fire cannot be fully ruled out we recommend providing a fire extinguisher in the immediate vicinity of the unit Fi...

Page 11: ...ions impermissible types of operation and potential hazards The unit may be operated maintained and repaired only by personnel of minimum statutory age who have been autho rized trained and instructed...

Page 12: ...nnot be damaged by heat or oil or by being driven over crushed pulled or similar Regularly check the power supply cord for signs of damage Do not operate the sasoo if the power supply cord is not in g...

Page 13: ...hed or are protected by fixed guards which are securely attached and require the use of tools for removal The system satisfies protection class I in accordance with EN 60 335 RESIDUAL RISK Electric sh...

Page 14: ...r inserts and other accessory parts must be disposed of in accordance with the applicable rules and regulations RESIDUAL RISK If disposal is not performed correctly there may be a health risk and a ri...

Page 15: ...nd technical data The rating plate is an integral part of the unit and must never be removed or altered The specification of the type is unit dependent Rating plate sasoo aircleaner 230 V 50Hz 4 A Uni...

Page 16: ...r chamber 3 Unit door 4 Exhaust grille 5 Stand with swivel joint 6 LED light for status indication 7 Potentiometer for setting the extraction power 8 Filter reset button 9 Boost button for temporary a...

Page 17: ...17 aircleaner Unit components and technical data Technical depiction...

Page 18: ...6 fold air exchange up to 122 m approx 50 m with 2 3 m ceiling height Room volume 6 fold air exchange boost mode up to 232 m aprox 100 m with 2 3 m ceiling height Electrical connection Rated voltage 1...

Page 19: ...e resistant Equipment Continuously adjustable air flow control Boost mode CO2 sensor Indicator for indicating room ventilation Filter change indicator Scope of supply sasoo aircleaner Stand 2 braked a...

Page 20: ...ect the sasoo to the 230 V 50 Hz power supply using the mains cable and plug provided The power supply line must be fuse protected with at least 5 A Do not touch the unit with wet hands or when standi...

Page 21: ...s through the HEPA filter in the sasoo Aerosols viruses and other extremely fine particles in the nanoscale range are filtered out of the air at a separation efficiency of 99 995 3 The activated carbo...

Page 22: ...of health protection and has been proven to reduce aerosol exposure for rooms up to 100 m and thus the risk of infection A 6 fold air exchange is recommended Source Deutsches Beratungszentrum f r Hygi...

Page 23: ...necessary Before starting the installation Check the unit and the filter for any transport damage Report any damage to the transport company Compare the delivered unit with your order Remove all tran...

Page 24: ...efully place the unit on the unit stand and lower it 3 Screw the grub screw into the nut using an Allen key to secure it The unit can rotate so it can be orientated to meet the respec tive requirement...

Page 25: ...nt the unit castors according to the illustration Allen key Notice Mount castors with brake side by side 3 Place the unit stand at the instal lation site Apply the brakes to the castors 4 Carefully pl...

Page 26: ...brake pull the brake lever upwards Danger Moving the unit by means of the mobile stand with castors is only permitted on even surfaces When rolling on inclined planes there is a risk of losing control...

Page 27: ...side of the unit using a tool 1 and open the unit door Install the filter according to the filter replacement instructions Close the unit door and close the latches again Perform a full visual inspec...

Page 28: ...requirement using the potentiometer 3 At full power this makes it possible to clean a room with up to 122 m with 6 times air exchange per hour Operation The extraction power can be continuously incre...

Page 29: ...long period of time 1 month Shutdown Display Status Constant green Normal operation Flashing red Filter replacement necessary after 1 500 operating hours see page 31 Constant orange 1 000 ppm CO2 in...

Page 30: ...ilter status and replace the filter insert if necessary Regularly after 1 500 operating hours The HEPA filter needs to be changed and this is indicated by the red flashing indicator light Annual inspe...

Page 31: ...indicator light signals the status of the HEPA filter Saturation of the adsorption filter is not indicated via the indi cator light Depending on the amount of contaminants the activated carbon filter...

Page 32: ...nit flashes red it is necessary to change the HEPA filter To change the filter proceed as follows 1 Switch off the unit and disconnect the power plug 2 Open the side latches on the door using an Allen...

Page 33: ...33 aircleaner Maintenance and servicing 3 4 5 Carefully remove the saturated filters 4 and place them in a suitable disposal container that can be closed with an airtight seal...

Page 34: ...9 Reset the filter status To do this press the reset button for 7 seconds After a successful reset the indicator light will turn white for 10 seconds Afterwards the status changes to green and the uni...

Page 35: ...key 4 Reconnect the power plug Do not put any unit into operation that is damaged or incomplete The owner of the waste in this case usually the producer of the waste is responsible for disposing recyc...

Page 36: ...Repair by specialist specialist dealers Unit fuse defective Replace fuse Insufficient extraction and filtration power Obstruction of the air passage Check the intake and exhaust air ducting Filters ar...

Page 37: ...bon filter inserts 4 00737 Always state the article number when placing your order Use only genuine spare filters from ULT AG to ensure the safety and functional reliability of the unit Any and all of...

Page 38: ...for waste electric equipment Stiftung Elektro Altger te EAR in accordance with the EU Directive WEEE Directive 2012 19 EU and the German Electrical and Electronic Equipment Act ElektroG We accept no r...

Page 39: ...39 aircleaner EU declaration of conformity...

Page 40: ...40 aircleaner Confirmation of the first electronic test...

Page 41: ...41 aircleaner...

Page 42: ...42 aircleaner...

Page 43: ......

Page 44: ...ULT AG Am G pelteich 1 02708 L bau Germany Tel 49 35 85 41 28 0 Fax 49 35 85 41 28 11 info sasoo aircleaner com www sasoo aircleaner com...