Information 

 

• Keep this manual so that it is accessible to professionals and future needs.                      
• Read this manual carefully before starting up the boiler.                 
• The efficiency of the boiler is calculated after the maximum amount pellets that can be fed and 
combusted in the burner during 1 hour (intended for combustion of normal wood pellets as an 
average of the fuel specification).             
• Follow the manual and its instructions carefully do recommended management and maintenance.  

 

Registration to the local building authority in your municipality      
 

N.B.: At every change of heating system, the local building authority of the municipality has to be 
contacted and a so called “Construction Registration” is made. 
 

Inspection           

Heating plants installed today shall be inspected and approved by authorized inspector like the local 
certified chimney-sweeper. The local building authority in the municipality can inform you how this 
could work.  

 

Important at installation  

• Make sure expansion and cold water connection are correctly mounted, if you are unsure you may        

control this by looking down in the connection pipes. The long pipe reaching down towards the 
bottom of the boiler is cold water and the short expansion connection. The pipe connections are 
placed behind the connection of the shunt valve. (See connection schedule on page 5-6.)     

• Make sure that boiler and heating system is water filled and de-aerated before starting the 

combustion.  

• Installation shall be made by certified ventilation and sanitation engineer and electrician.  
• At operation with burner: Set the thermostat so that the immersion heater will be connected at 

unintentional interruptions in operation of the burner. 

•. 

N.B.! 

The burner shall be inserted to maximum in the boiler. Control this carefully in the future also 

if the burner is disconnected for example cleaning and service.         

• At adjustment of the burner draw limiter shall be adjusted after the draft condition of the chimney.    . 
• The boiler shall be connected electrically via an all-pole breaker with at least 3 mm length of break.   
• The room giver should be on level zero when the boiler is put into operation, when the boiler then is 

filled with water and reached maximum temperature the giver should be turned up to approx. 25 
degrees so that a click is heard in the giver and then turned back to desired indoor temperature. By 
doing this you activate (start) the circulation pump.  

 
Sweeping 

Chimney sweeping made in accordance with the fire-protection law shall be made frequently during 
the year. This is made by your local chimney sweeper. Regular cleaning of heating surface of the 
boiler shall be made in a way so that good operating economy is obtained. Prepare sweeping by 
turning off the boiler at least a couple of hours before cleaning to minimize the amount of ignited ash.  
 

Warning! 

See to that the power to the boiler is turned off before the cap over the burner is removed and 
dismount cabling to the burner when the burner is removed from the boiler.  

 
Maintenance agreement increases operation length and life of the unit          

ULMA AB recommends subscription of annual maintenance agreement.        
For more information contact your local ULMA retailer.                 

 
Change of wear parts   

ULMA AB always recommends that wear parts, when needed, are being changed by an authorized 
service technician at your ULMA retailer. ULMA’s retailers can provide necessary spare parts and at 
change make sure that the part being changed on the unit go through alignment and that a flue-gas 
analysis of the unit is made.  

 

Summary of Contents for LAMBDA

Page 1: ...1 INSTALLATION AND MAINTENANCE OF THE ULMA LAMBDA BOILER 20KW ...

Page 2: ... diagram 8 6 Installation 9 7 Boiler room and chimney 10 8 Management and maintenance 11 9 Data about pellet firing 12 10 Declaration of conformity 13 12 Test record 14 ULMA AB Energigatan 11 SE 512 53 Svenljunga Sweden Phone 46 0 325 17680 E mail info ulma se www ulma se ULMA AB reserves the right to changes in details and specifications without a preceding message ...

Page 3: ...on of the burner N B The burner shall be inserted to maximum in the boiler Control this carefully in the future also if the burner is disconnected for example cleaning and service At adjustment of the burner draw limiter shall be adjusted after the draft condition of the chimney The boiler shall be connected electrically via an all pole breaker with at least 3 mm length of break The room giver sho...

Page 4: ... for combustion of pellets but is also provided with a 6 kW immersion heater Sweeping Regular cleaning of heating surfaces is made from the top by taking off the lid placed in the center on the top of the boiler The boiler is provided with an extra large ash box in the bottom part to facilitate the maintenance The ash box is emptied as required approx 1500 Kg pellet Normally 3 4 times per year is ...

Page 5: ...n boiler rooms that normally would be considered tight The pipe joints are located on the top of the boiler The electrical installation is easily made via already existing cables and you do not have to demount any parts for this procedure Service of the boiler is easy to make since all connections and components are easily accessible from the front ...

Page 6: ...me 200 L My chimney area 80 cm2 Connection hole burner Ø 154mm Dept of hearth 350mm Hight of hearth 350 mm Power connection 400 VAC Warranty 5 YEARS My under pressure 1 5 vp Efficiency Approx 90 92 Max effect 20kW Hot water coil 11m Immersion heater 6kW Ash box Approx 48 liters Weight Approx 250 Kg Technical data ...

Page 7: ...7 Building services installations schedule for ULMA LAMBDA 20kW pellet boiler ...

Page 8: ...8 Wiring diagram ...

Page 9: ...he valves of the system are open 4 that potential control and safety automatic system is working 5 that the chimney has required draft and that the fresh air ventilation is open Safety valve If a closed expansion tank is installed to the radiator system the safety valve should be controlled 3 4 times per year Activate the valve by pressing or turning the control and then make sure that water is en...

Page 10: ... chimney or bricked chimney with flue lining tube will not be as easily damaged of low flue gas temperatures provided that possibly condensate is continuously drained from the lowest point of the chimney This is the responsibility of the installer to control at installation Place the boiler at least 100 mm from the wall bricks to facilitate service Also leave room for possibly existing cleanout do...

Page 11: ... heating surfaces The tubes shown on this picture without the flue gas break that you can see on the picture to the left O B S Very important to put where flue gas in a proper manner after completion of sweeping See picture above Be extra attentive of to the quality of the pellets at new delivery or change of deliverer At new delivery a flue gas analysis should be made Therefore we recommend a ser...

Page 12: ...uthorities The carbon dioxide taken up and captured during the growth of the trees is released in the process to once again be taken up by the nature In other words a circuitry Combustion of pellets does not provide the atmosphere extra carbon dioxide which happens at combustion of the fossil fuels oil gas and coal Comparison tables between Svanen market Norsk Pellets and Swedish standard SS 18 71...

Page 13: ...13 ...

Page 14: ...tion power to burner 5 Functional inspection immersion heater Grey_____Ω Brown_____Ω Black_____Ω 5 Serial no 6 Control of content in packaging Fiberglass cord Sweeping brush Manual Clutch kit mixing valve relief valve Checked and approved by ______________________________ Name ______________________________ 8 Control of accessories supplied Smoke pipe Draft limiter Checked and approved by ________...

Reviews: