SUSPENDED INSTALLATION
Step 1:
Accessories
Step 2:
Drill hole in the ceiling, push the rubber plug into the ceiling, fix the fixing head 2 in the ceiling with 4X30PA screw.
Step 3:
A. Suspended method on the left: thread the square-head screw through fixing hole of safety rope, clamp and
8-figure buckle,and fixed with sewing machine
B. Suspended method on the right: thread the square-head screw through fixing hole of safety rope,clamp, and
fixed with sewing machine.
Step 4:
A. Suspended method on the left: thread the power wire through 8-figure buckle fixed on the left, then install the
whole set of fixing clip on the lamp;
B. Suspended method on the right install the clip on the lamp.
Step 5:
Fix the fixing head 1 with fixing head 2 tightly, and adjust suspended rope with sewing machine to
balance the lamp, finally connect input wire of lamp.
L
N
D+
D-
GND
L
N
D+
D-
GND
G
K
L
F
H
I
J
A
B
C
D
E
ITEM
A. LA618 LAMP BODY
B. SQUARE-HEAD SCREW
C. SAFETY ROPE
D. CLIP
E. SEWING MACHINE
F. SUSPENDED ROPE
G. FIXING HEAD 1
H. 4X30PA SCREW
I. FIXING HEAD 2
J. RUBBER PLUG
K. 8 FIGURE BUCKLE
L. DOUBLING CLAMP
QTY.
1
2
4
2
2
2
2
2
2
2
1
4
STEP 1
STEP 4
STEP 2
STEP 3
STEP 5
LA618 SUSPENDED
INSTALLATION INSTRUCTIONS
www.ullighting.net | 718.726.7500
U.L. Lighting Fixtures Corp.
Specifications and data subject to change without notice. Consult factory when critical.
Consult factory for additional configurations and options not listed or shown.
Visit our website for the most current data
Rev. 05/2017
Page 2 of 4
APPLIES TO MODELS
LA618-2, LA618-4, LA618-5