background image

Notice

     Maximum resistive load: 10A/120V, 1200W.
     Power meter range:

i. Measure voltage range: 100~120VAC

ii. Measure current range: 1~10A

iii. Measure power range: 30~1200W

iv. The accumulate period is by month, and the maximum period is 3 months. (The earliest period is 1 year ago)

     When the Power Switch works as a router, the maximum joined sensors is 16. The maximum router in a system is 16. 
     The maximum wireless signal cascade-able is 3 levels. 

Troubleshooting

Problem 

Solution

Specifications

Wireless Power Switch (US)

The LED indicator lights abnormally 

when linking to the system

Cannot link to the system 

a. Make sure the device is properly connected to the wall outlet.
b. Reset to factory default (Please see 

Installation

,

 IV. Device Deletion

), and    

  

re-join to the system.

c. If the problem persists, please contact your local distributor.

Check the wireless signal and the distance between device and Gateway/Router 

(line of sight) is 300 meters (max.). If there is any obstructions (i.e. walls or metal 

objects) between the devices, the distance will be shorter. Users can move the 

device closer or add a Router,then try again.

Communication Protocol / Frequency

Operation Range

Operation Voltage 

LED Indicator

Operation Interface

Resistive Load

Inductive Load (Single Face)

Over Current Protection

Output Load Current Range

Output Load Power Range

Operating Temperature

Storage Temperature

Humidity

Dimension (W x H x D)

Weight

Zigbee Pro ZHA1.2 / 2.4 GHz ISM band

Up to 300 meters (LOS)

100~120VAC

Blue 1PC/Red 1PC , LED Status: Relay (ON/OFF)

Push button

10A/120VAC, 1200W max

0.5HP/120VAC

11A

1~10A±10%

30~1200W±10%

0°C ~ 40°C (32~104°F)

-20°C ~ 70°C (-4~158°F)

90% RH Max, Non-Condensing

82mm x 59.5mm x 53.7mm

77g

Installation (Continue)

IV. Device Deletion 

3. Delete the device from the website.

(See the features on the right side.)

4. Long press the SET button for 6 seconds.

The LED indicator blinks blue and then

turns off. After 6 seconds, the LED

indicator blinks again (faster) and then

turns off again, indicating the deletion

process is sucessful. (Please complete

the procedure in 3 minutes.)

1

2

3

Note: 

After device deletion, it will back to auto joining mode.

RF exposure warning statement

Reviews: