Notice
Maximum resistive load: 10A/120V, 1200W.
Power meter range:
i. Measure voltage range: 100~120VAC
ii. Measure current range: 1~10A
iii. Measure power range: 30~1200W
iv. The accumulate period is by month, and the maximum period is 3 months. (The earliest period is 1 year ago)
When the Power Switch works as a router, the maximum joined sensors is 16. The maximum router in a system is 16.
The maximum wireless signal cascade-able is 3 levels.
Troubleshooting
Problem
Solution
Specifications
Wireless Power Switch (US)
The LED indicator lights abnormally
when linking to the system
Cannot link to the system
a. Make sure the device is properly connected to the wall outlet.
b. Reset to factory default (Please see
Installation
,
IV. Device Deletion
), and
re-join to the system.
c. If the problem persists, please contact your local distributor.
Check the wireless signal and the distance between device and Gateway/Router
(line of sight) is 300 meters (max.). If there is any obstructions (i.e. walls or metal
objects) between the devices, the distance will be shorter. Users can move the
device closer or add a Router,then try again.
Communication Protocol / Frequency
Operation Range
Operation Voltage
LED Indicator
Operation Interface
Resistive Load
Inductive Load (Single Face)
Over Current Protection
Output Load Current Range
Output Load Power Range
Operating Temperature
Storage Temperature
Humidity
Dimension (W x H x D)
Weight
Zigbee Pro ZHA1.2 / 2.4 GHz ISM band
Up to 300 meters (LOS)
100~120VAC
Blue 1PC/Red 1PC , LED Status: Relay (ON/OFF)
Push button
10A/120VAC, 1200W max
0.5HP/120VAC
11A
1~10A±10%
30~1200W±10%
0°C ~ 40°C (32~104°F)
-20°C ~ 70°C (-4~158°F)
90% RH Max, Non-Condensing
82mm x 59.5mm x 53.7mm
77g
Installation (Continue)
IV. Device Deletion
3. Delete the device from the website.
(See the features on the right side.)
4. Long press the SET button for 6 seconds.
The LED indicator blinks blue and then
turns off. After 6 seconds, the LED
indicator blinks again (faster) and then
turns off again, indicating the deletion
process is sucessful. (Please complete
the procedure in 3 minutes.)
1
2
3
Note:
After device deletion, it will back to auto joining mode.
RF exposure warning statement