UI SP-556 series Operation Manual Download Page 1

 

 

 

【Operation Manual】 

 

Digital speed meter 

 

M O DEL: SP-5 5 6  Se rie s 

 

Series 

name 

Output 

Input 

Sensor 

Power 

Power  type  Color  Cover 

Function 

SP-556 

 

 

 

 

 

 

 

 

 

 

 

 

Preset output two point 
(NPN open collector output) 

 

No 

code 

 

 

 

 

 

 

 

 

 

 

 

7segment red LED 

 

GL 

 

 

 

 

 

 

 

 

 

 

 

7segment green LED 

 

 

P2 

 

 

 

 

 

 

 

 

 

 

Two point Photo MOS relay output 

 

 

 

AV3 

 

 

 

 

 

 

 

 

 

Analog voltage output (DC 1-5V) 

 

 

 

AV4 

 

 

 

 

 

 

 

 

 

Analog voltage output (DC 0-5V) 

 

 

 

AV5 

 

 

 

 

 

 

 

 

 

Analog voltage output (DC 0-10V) 

 

 

 

AI 

 

 

 

 

 

 

 

 

 

Analog current output (DC 4-20mA) 

 

 

 

 

B *1 

 

 

 

 

 

 

 

 

BCD output 

 

 

 

 

 

BI *1 

 

 

 

 

 

 

 

BCD input 

 

 

 

 

 

 

No 

code 

 

 

 

 

 

 

NPN Open Collector pulse input 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage pulse input 

 

 

 

 

 

 

V3 

 

 

 

 

 

 

Tacho-generator signal input AC 0.8V-80V(P-P) 

 

 

 

 

 

 

 

 

 

 

 

 

Sine wave signal input  AC 0.05V-20V(P-P) 

 

 

 

 

 

 

L1 

 

 

 

 

 

 

Line receiver 1CH (A・A) input 

 

 

 

 

 

 

F2 

 

 

 

 

 

 

Current modulation pulse input(A-input) 

 

 

 

 

 

 

F2W 

 

 

 

 

 

 

Current modulation pulse input(A-input, B-input) 

 

 

 

 

 

 

 

HI 

 

 

 

 

 

High-speed input (0.01Hz~120kHz) 

 

 

 

 

 

 

 

 

No 

code 

 

 

 

 

DC12V 100mA 

 

 

 

 

 

 

 

 

S24 

 

 

 

 

DC24V 60mA 

 

 

 

 

 

 

 

 

 

No 

code 

 

 

 

Power source:AC 100V-240V 

 

 

 

 

 

 

 

 

 

DC *2 

 

 

 

Power source:DC 12V-24V 

 

 

 

 

 

 

 

 

 

 

DM *3 

 

 

Unredeemable type 

 

 

 

 

 

 

 

 

 

 

 

No 

code 

 

Gray 

 

 

 

 

 

 

 

 

 

 

 

 

Black 

 

 

 

 

 

 

 

 

 

 

 

 

No 

code  not attached 

 

 

 

 

 

 

 

 

 

 

 

 

Terminal stand cover 

 
          *1  “B”  Option and  “BI”  Option cannot be selected together. 
          *2 Optional  “DC”  is outside CE marking. 
          *3 The meter is an subject of CE Marking. But box-type (DM) is off the subject of CE Marking. 
 
 

【  8th      8  Sep.  2015  】 

                                                                                                                                            @SP-556CE(8)-E 

Summary of Contents for SP-556 series

Page 1: ...ulse input F Voltage pulse input V3 Tacho generatorsignalinputAC 0 8V 80V P P N Sine wave signal input AC 0 05V 20V P P L1 Line receiver 1CH A A input F2 Currentmodulationpulseinput A input F2W Curren...

Page 2: ...ry cloth when you clean the meter Caution Devices to be connected to each terminal of the terminal block use the one that is properly isolated from hazardous live parts Caution Since there is no power...

Page 3: ...ting Mode Sampling time Mode Hold function setting display blank lowest digit display Mode OUT1 Preset output open collector output Mode OUT2 Preset output open collector output Mode OUT3 Preset outpu...

Page 4: ...nteed period and a guaranteed area Guaranteed period The period a product guarantees is 4 years from a delivered day Guaranteed area If we trouble by responsibility in whole guaranteed period it s rep...

Page 5: ...fixed at 0 or 0 5 selectable Moving average Averaged by 1 19 input pulses selectable Auto zero time The time 0 5 120 sec selectable following input stop at which the reading returns to zero Measureme...

Page 6: ...on Output condition Judgment output is compared with the indication value by pre set value Output system NPN Open collector output 2 stages DC 30V 50mA max Output indication During preset output the O...

Page 7: ...sometimes falls from 4000 by setting of Mode No C and d BCD output B option Output terminal Output from BCD optional connector Output type All digits parallel open collector output Output timing Synch...

Page 8: ...er The meter is fixed right and left both sides Fig 3 Caution 1 Please install it horizontally 2 Fit the body on to a panel 1 0 4 0 mm in thickness 3 Please do not tighten the screw of the mounting br...

Page 9: ...preset output is set OUT1 4 that is setting it now is displayed Each input display lamp Measurement state When Mode No 0 BC is 02 07 ratio measurement the measurement display switch of Ratio measureme...

Page 10: ...t state When Mode No 0 BC is 00 A input measurement or 01 B input measurement The teaching function works Refet to P 35 Teaching function Setting state When each setting it a set digit is shifted to a...

Page 11: ...of the sensor Wire correctly referring to the connection diagram P 9 and the manual of the sensor The sensor and the meter might break down when connecting it by mistake Do not use the sensor power s...

Page 12: ...r D Line driver encoder Fig 8 Fig 9 E Pulse output 3 wire type sensor F Current pulse input 3 wire pulse sensor Fig 10 Fig 11 G Current pulse input 2 wire pulse sensor Fig 12 NOTE When mis counting by...

Page 13: ...t Hold input Fig 14 Fig 15 Tacho generator signal input Sine wave signal input Line driver input Fig 16 Fig 17 100K 12V Sensor power or 3 6 7 8 5 12V 2 2K SW5 6 470 30V 1 5K 3V 1 5K 3V 30V 100K 470 SW...

Page 14: ...z 50Hz LOW ON OFF OFF ON Input frequency 0 01Hz 1kHz MID OFF ON ON OFF Input frequency 0 01Hz 10kHz HI OFF OFF OFF OFF Input frequency 0 01Hz 120kHz OFF OFF OFF OFF NPN open collector input ON ON Volt...

Page 15: ...The setting menu Test Mode Power supply OFF Test mode Turn power supply on with E N T R ST M ode M ode M ode M ode M ode M ode M ode M ode M ode M ode M ode M ode M ode E N T R ST E N T RST being pres...

Page 16: ...Press for 2sec or more BCD input setting option 0 0 1 The preset value setting The mode setting F 0 0 0 0 1 0 0 0 0 0 2 0 0 Press for 2 sec or more Teaching E N T E NT E NT E NT E N T E N T R ST E N...

Page 17: ...Initialization Throw power supply in with pressed to initialize the settings After the initialization the set values will be as shown in Table 2 Table 3 Mode protect function are also cleared Caution...

Page 18: ...sh figure is down A figure of flash indication is shifted Each time the key is pressed a flash figure is shifted to the right 0 9 A b C d E F The Mode No is changed Each time is pressed the Mode No is...

Page 19: ...measurement sum measurement A B 07 Ratio measurement differential rate measurement A B R or A B R 08 Passing time measurement 09 Shot speed UA 2 sensor one direction speed 10 Shot speed UB1 1 senor on...

Page 20: ...No Sampling time Mode No Setting of the preset output Std Mode No Option Mode No Setting of the analog output Option Mode No Setting of the reverse rotation input Mode No Operation explanation A input...

Page 21: ...is mode Set the unit of scaling in mm Refer to Mode No 5 Oven length tact pitch setting Oven length tact pitch Ex Shot speed type 2 sensor one direction speed type 1 senor one direction speed type 1 s...

Page 22: ...stopped Sensor input B works as input in a lap time When ON is considered to be it during time measurement the indication is performed hold of but can continue measuring the time Then When B sensor in...

Page 23: ...1 B input 03 07 Ratio measurement 09 12 Shot speed 3 hour minute becomes 1 minute 4 minute second becomes 2 second When it is chosen Passing time measurement Cycle timer Stop watch A and B by a measur...

Page 24: ...easuring types 09 12 shot speed set the distance between the sensor Ex Using a flow sensor which emits 1 pulse per 1 234mL the cumulative total flow in liters can be expressed using the following conv...

Page 25: ...left side or the right side Sensor The right side can be adjusted slightly Ex 2 Revolution Factor revolution 30 pulse Mode No 1 Exp value Mode No 2 Sensor Please register scaling data of Mode No 1 and...

Page 26: ...averaged and indicated This function should be applied only at 20 Hz or less Ex Signal output Detecting block Input pulse First time Moving Second time Flow average range Third time For example if fit...

Page 27: ...e last input signal Mode No B input Setting of scaling data Scaling data 0001 9999 Do not set 0000 Setting method same as Mode No 1 A input Setting of scaling data Mode No B input Exp value moving ave...

Page 28: ...uring types 0 Passing time measurement setting Oven length tact pitch 00 01 99 99 m unit m Do not set 00 00 Decimal point position is fixed Oven length tact pitch setting For this mode setting is nece...

Page 29: ...use it for preventing the flashing or for stabilizing the display Accordingly renewal shall be made by averaging the display for each set time With the setting of 00 0 display is made for each pulse...

Page 30: ...blinking 2 Bottom hold Between ON it updates a smallest value indication level while blinking 3 Hold Between ON It displays a current value while blinking 4 Reverse rotation input differential rate m...

Page 31: ...exceeds the upper lower limit setting value preset value The presetting output once activated is sustained until reset 2 9 One shot output A pulse of pre specified width is output once when the indic...

Page 32: ...as Mode No 8 OUT1 Ex With the judging output inhibition time 30 seconds down limit is selected and output mode 50 ms 1 shot is selected then setting is made as follows 4 Mode No OUT3 Preset output ph...

Page 33: ...5 100 ms 1 shot 1 Hold 6 250 ms 1 shot 2 10 ms 1 shot 7 500 ms 1 shot 3 20 ms 1 shot 8 1 sec 1 shot 4 50 ms 1 shot 9 2 sec 1 shot Up limit down limit selection 0 Up limit 1 Down limit 2 Down limit del...

Page 34: ...et Mode No 0 00 A input or 01 B input or 08 Passing time measurement Otherwise set it in 1 Synchronizes for the display 1 Synchronizes for the display The analog output is output for an indication val...

Page 35: ...ng of maximum output ndication 5000 NOTE he analog output outputs it at absolute value for an indication level There are no relations in a plus and the minus of the indication level In the case of the...

Page 36: ...op when using it excluding with the BI type Selection of BCD input Using BCD input I select which Preset output I operate Caution When it is with an P2 option OUT3 and OUT4 works When there is not BI...

Page 37: ...de protect Operation key Indication Procedure The mode protect present Press the key for 2 sec or more The present mode protect state is displayed The regular factory setting is L off The mode protect...

Page 38: ...lamp blinks In the case of B input measurement B input lamp blinks A figure of flash indication is shifted Each time the key is pressed a flash figure is shifted to the right 0 9 Push this key for cha...

Page 39: ...eset value is displayed and can set it Push key The OUT2 lamp shifts to OUT3 lamp OUT3 lamp lights up and a current preset value is displayed and can set it Push key The OUT3 lamp shifts to OUT4 lamp...

Page 40: ...he zero volume to adjust 100 5 V Turn the span volume to adjust Repeat the procedure several times for fine adjustment Voltage output AV4 type unit Indication Output voltage 0 0 V Turn the zero volume...

Page 41: ...at the factory Please do not touch except necessity V3 type Tacho generator signal input AC 0 8 to 80V P P N type Sine wave signal input AC 0 05 to 20V P P Adjustment method The sensitivity adjustment...

Page 42: ...tive The state that an emitter does not conduction with the collector of the output transistor when data output it 4 When I take in data because TI take up inhibition signal is output at the time of d...

Page 43: ...update data I turn off a latch Uptake possibility and take in data and ON does a latch Uptake prohibition again Latch Short When Latch Pin 37 and GND are in a short state I prohibit the uptake of data...

Page 44: ...utput 1 2 A B M ode 3 4 E N T R ST 4 130 111 15 114 96 48 130 or more 0 5 0 45 0 8 0 92 Unit mm 70 or more Unit mm Packing attachment Plaese use packing of attachment If use by the IP66 The terminal...

Page 45: ...42 Unredeemable type Option DM Fig 28...

Page 46: ...of noise power supply line and inverter make it as short as possible After that please install a sensor code A great many noises may be included in F G Line of the device In this case you should not...

Page 47: ...test mode Refer to P 12 Initialize Refer to P 14 When it still does not resume normal status have it serviced Remains at 0 Is the setting for each mode correct Is the sensor input normal Is the distan...

Page 48: ...curacy of the sensor when there is little quantity of detection Noise countermeasure Refet to P 43 When it is caused by the chattering such as relays Please attach a capacitor to the sensor input term...

Page 49: ...46...

Page 50: ...47 MEMO...

Page 51: ...48 MEMO...

Page 52: ...Head Office Technical inquiry TEL 81 72 274 6001 FAX 81 72 274 6005 123 1 Kami Nishi Ku Sakai shi Osaka 593 8311 Japan Tokyo Office TEL 81 3 5256 8311 FAX 81 3 5256 8312 All specifications may be chan...

Reviews: