CX8946
O
PERATION
18
6
Operation
If an authorized transponder is held in front of the connected locking unit, a BLE
connection is established with the online module and, depending on the version,
the authorization is requested via the corresponding protocol of the third-party
system.
If no BLE connection can be established, for example in case of a power failure
or a wireless attack, the electronics of the locking unit drops back into offline
mode. In this mode the door can be opened with any transponder with offline
authorization.
In this case the electronics of the locking unit warns the user, however, before
opening with a distinctive visual and acoustic signaling.
When the locking unit is woken up, for example by a knob cylinder being turned
or a door handle or knob module being actuated, a wireless connection is also
established.
6.1
Reset
Tap the reset button
or disconnect the device from the power supply
(here LAN connection).
6.2
Resetting the configuration (factory reset)
Restarting configuration tools via Wi-Fi, as described in more detail in chapter
5.2.3 "Configuration of the network interface", resets the settings made. To this
purpose the
button must be held down while the unit performs a reset.
6.3
Firmware updates
The update tool "Clex FW Prog" is available to update the firmware of
the module. Contact your respective Integration partner.
The LAN interface has its own firmware, which can be updated via the web
interface (see section 5.2.3).
8
7