background image

 
 

 

 

CX6162/66 

Clex prime  
Compact electronic knob cylinder 

Operating and 
assembly manual 

 

Summary of Contents for CX6162

Page 1: ...CX6162 66 Clex prime Compact electronic knob cylinder Operating and assembly manual...

Page 2: ...ergstra e 2 4 97297 Waldb ttelbrunn Germany Tel 49 931 40672 0 E Mail contact UundZ de http www UundZ de This operating and assembly manual is copyright protected The information contained this manual...

Page 3: ...anagement accessories 13 4 Assembly 14 4 1 General assembly instructions 14 4 2 Assembly 14 5 Commissioning 15 5 1 Initial commissioning 15 5 2 Managing the locking system 16 5 3 Configuring the knob...

Page 4: ...ruptions or hazards such as non access to injured personnel malfunctions property damage or other damages resulting from non compliance with this operating and assembly manual or incorrectly configure...

Page 5: ...locks The applicable regulations should be followed The CX616x should not be used if the housing or the electronics is damaged Changes or retrofits to the product are not allowed The knob module shou...

Page 6: ...ing No cabling required Can be combined with other systems for example Clex private Versions for MIFARE and LEGIC Transponder can be supplied 3 1 1 Authorisations There are up to 296 groups in the Cle...

Page 7: ...tions are programmed in the key in the Clex prime system The following time restrictions are possible Total interval Day interval Weekly schedule Holidays Special time zones For detailed information o...

Page 8: ...the knob cylinder is accompanied with flashing of red light 5 times and 5 short audible signals The battery needs to be changed If an authorized key is held in front of the reading unit then the red L...

Page 9: ...Phase 3 Manipulation Toggle off Toggle On Unknown position Service mode Radio diagnosis Automatic wake up off Wireless opening not OK Wireless opening OK The following information are recorded for ev...

Page 10: ...d scope of supply 3 2 1 CX6162 1 Grub screw 5 Battery 2 Mechanical knob 6 Electronic knob 3 Fixing screw 7 Knob cover 4 Cylinder casing 3 2 2 CX6166 1 Fixing screw 4 Electronic knob 2 Half cylinder ca...

Page 11: ...T DESCRIPTION 10 3 3 Variants Different variants of the electronic knob cylinder are available for selection For indoor or outdoor use Various cylinder casing lengths Basic version without date time a...

Page 12: ...the mechanical knob 20 0mm Diameter of the mechanical knob 29 0mm Transponder Version 1 MIFARE MIFARE Classic MIFARE DESFire Active transponder 868MHz Version 2 LEGIC LEGIC prime LEGIC advant MIFARE D...

Page 13: ...SCRIPTION 12 3 4 3 Dimensions 3 5 Standards The electronic knob cylinder CX616x meets the following standards EN 15684 2013 being prepared EN 60529 2014 being prepared A B 44 3 20 0 29 0 31 4 A 10 44...

Page 14: ...elevant data can be sent directly to all the locking system components of Clex prime that are provided with a radio chip 3 6 4 CX6520 Programming station The programming station is an optional additio...

Page 15: ...always check if the components can move freely After assembly check the function with the door open 4 2 Assembly Insert the cylinder housing along with the electronic knob into the lock Tighten the f...

Page 16: ...e are two options of changing over to the normal operating mode Option 1 Turn the knob a few times to wake up the reading unit till an LED starts glowing Hold up the key in front of the reading unit o...

Page 17: ...age 18 Wake up sensitivity see chapter 6 1 Automatic wake up page 17 Expiry date of a key see chapter 3 1 3 Automatic expiry date page 6 Radio response of the knob cylinder wake on radio mode The auth...

Page 18: ...lic objects in the surroundings without reading a key then automatic wake up is disabled In this case the knob cylinder has to be woken up manually Turn the knob a few times to wake up the reading uni...

Page 19: ...g the door handle in the unlocked state The time duration for which the knob cylinder remains engaged can be configured 1 to 15 seconds the default value is 5 seconds After successful authorization en...

Page 20: ...g Key authorised Green LEDs start glowing Timer circuit toggling On Long loud beep green LEDs start glowing Timer circuit toggling Off Long loud beep red LEDs start glowing Reset Long low beep all the...

Page 21: ...ry CAUTION Danger of injury caused by improper use Do not charge open or heat the battery Always replace discharged batteries with new batteries Pay attention to the correct polarity when inserting th...

Page 22: ...er as far as it goes onto the knob so that the marked spot on the knob cover aligns with the protruding plastic part on the knob The knob cover has to be inserted such that only the rubber seal is vis...

Page 23: ...g CAUTION Damage to the sealing ring caused by improper handling Do not use any sharp objects and do not stretch the sealing ring more than what is required for mounting Precondition Knob cover is rem...

Page 24: ...rror 5 long beeps 2 short beeps RTC fault clock 5 long beeps 3 short beeps Internal error unhandled interrupt 5 long beeps 4 short beeps Internal error bus conflict 5 long beeps 5 short beeps Internal...

Page 25: ...POSAL 24 9 Disassembly and Disposal 9 1 Disassembly Loosen the Allen screw of the mechanical knob and remove the mechanical knob from the cylinder Remove the fixing screw Remove the cylinder body and...

Page 26: ...should be in accordance with the European Directive 2002 96 EC at a collection point for electrical waste Defective or used batteries should be recycled in accordance with the European Directive 2006...

Page 27: ...contains the authorization information This can for example be an ISO card or a chip The key is sometimes also known as transponder Service unit Data can be exchanged between a PC having the Keyvi man...

Reviews: